Literature DB >> 15583566

Fabrication of a cement- and screw-retained implant prosthesis.

Manoj Rajan1, R Gunaseelan.   

Abstract

The advantages of cement-retained implant-supported restorations over screw-retained implant restorations are well documented. Difficulty with prosthesis retrieval and excess cement removal may be experienced with cemented restorations. The technique described allows for the fabrication of a retrievable cemented prosthesis that is simple, practical, and effective.

Mesh:

Year:  2004        PMID: 15583566     DOI: 10.1016/j.prosdent.2004.09.009

Source DB:  PubMed          Journal:  J Prosthet Dent        ISSN: 0022-3913            Impact factor:   3.426


  8 in total

1.  Replacement of missing anterior tooth using screw retained implant prosthesis in the esthetic zone: a case report with 3 years of follow up.

Authors:  Manawar Ahmad; B Dhanasekar; I N Aparna; Hina Naim
Journal:  J Indian Prosthodont Soc       Date:  2012-10-19

2.  Effect of abutment neck taper and cement types on the amount of remnant cement in cement-retained implant restorations: an in vitro study.

Authors:  Yeon-Hee Park; Kyoung-A Kim; Jung-Jin Lee; Tae-Min Kwon; Jae-Min Seo
Journal:  J Adv Prosthodont       Date:  2022-06-27       Impact factor: 1.989

3.  The Effects of New Design of Access Hole on Porcelain Fracture Resistance of Implant-Supported Crowns.

Authors:  Reza Derafshi; Mitra Farzin; Masoumeh Taghva; Hossein Heidary; Berivan Atashkar
Journal:  J Dent (Shiraz)       Date:  2015-03

4.  The importance of prosthetic planning for implant-supported dentures in esthetic zones - A case report.

Authors:  Gustavo Vargas Da Silva Salomão; Fernando Toledo Santos; Sergio Allegrini Junior
Journal:  Int J Surg Case Rep       Date:  2018-11-27

5.  A Special Design to Facilitate Retrieval of Cement-Retained Zirconia-Based Implant-Supported Restorations.

Authors:  Mitra Farzin; Reza Derafshi; Rashin Giti; Masumeh Taghva
Journal:  J Dent (Shiraz)       Date:  2021-06

6.  Effect of screw access hole preparation on fracture load of implant-supported zirconia-based crowns: an in vitro study.

Authors:  Hadi Mokhtarpour; Reza Eftekhar Ashtiani; Minoo Mahshid; Farhad Tabatabaian; Marzieh Alikhasi
Journal:  J Dent Res Dent Clin Dent Prospects       Date:  2016-08-17

7.  Restoring a post-traumatic partial edentulous mandible with the Toronto prosthesis: a clinical report.

Authors:  Fatemeh Nematollahi; Marzieh Alikhasi; Elaheh Beyabanaki
Journal:  J Dent Res Dent Clin Dent Prospects       Date:  2018-06-20

8.  Load-Bearing Capacity of Zirconia Crowns Screwed to Multi-Unit Abutments with and without a Titanium Base: An In Vitro Pilot Study.

Authors:  Hadas Heller; Adi Arieli; Ilan Beitlitum; Raphael Pilo; Shifra Levartovsky
Journal:  Materials (Basel)       Date:  2019-09-20       Impact factor: 3.623

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.