Literature DB >> 15583079

Long-term clinical course of patients after termination of ventricular tachyarrhythmia by an implanted defibrillator.

Arthur J Moss1, Henry Greenberg, Robert B Case, Wojciech Zareba, W Jackson Hall, Mary W Brown, James P Daubert, Scott McNitt, Mark L Andrews, Adam D Elkin.   

Abstract

BACKGROUND: The implanted cardioverter defibrillator (ICD) improves survival in high-risk cardiac patients. This analysis from the MADIT-II trial database examines the long-term clinical course and subsequent mortality risk of patients after termination of life-threatening ventricular tachyarrhythmias by an ICD. METHODS AND
RESULTS: Life-table survival analysis was performed, and proportional hazards regression analysis was used to evaluate the contribution of baseline clinical factors and time-dependent defibrillator therapy to mortality during long-term follow-up. Of 720 patients with an ICD (average follow-up 21 months), 169 patients received 701 antiarrhythmic device therapies for ventricular tachyarrhythmias. Few baseline characteristics distinguished patients who received appropriate ICD therapy for their first ventricular tachyarrhythmic episode. The probability of survival for at least 1 year after first therapy for ventricular tachycardia (VT) or ventricular fibrillation (VF) was 80%. The hazard ratios for the risk of death due to any cause in those who survived appropriate therapy for termination of VT and VF were 3.4 (P<0.001) and 3.3 (P=0.01), respectively, compared with those who survived without receiving ICD therapy, with a high frequency of heart failure and late nonsudden cardiac death after first successful ICD therapy for VF.
CONCLUSIONS: Successful appropriate therapy by an ICD for VT or VF is associated with 80% survival at 1 year after arrhythmia termination. These patients are at increased risk for heart failure and nonsudden cardiac death after device termination of VT or VF and should receive special attention for the prevention and management of progressive left ventricular dysfunction during long-term follow-up.

Entities:  

Mesh:

Year:  2004        PMID: 15583079     DOI: 10.1161/01.CIR.0000150390.04704.B7

Source DB:  PubMed          Journal:  Circulation        ISSN: 0009-7322            Impact factor:   29.690


  136 in total

Review 1.  Telomerase-independent mechanisms of telomere elongation.

Authors:  H Biessmann; J M Mason
Journal:  Cell Mol Life Sci       Date:  2003-11       Impact factor: 9.261

2.  Clinical trials of antiarrhythmic therapies and optimizing health care resource deployment: the need for a paradigm shift.

Authors:  Sanjeev Saksena
Journal:  J Interv Card Electrophysiol       Date:  2012-01       Impact factor: 1.900

3.  [Is intraoperative ICD-testing still necessary?].

Authors:  C Mewis; H-R Neuberger; A Buob
Journal:  Herzschrittmacherther Elektrophysiol       Date:  2010-06

4.  Arrhythmias: Catheter ablation for prevention of ventricular tachycardia.

Authors:  Usha B Tedrow; William G Stevenson
Journal:  Nat Rev Cardiol       Date:  2010-04       Impact factor: 32.419

Review 5.  Current and future role of cardiovascular magnetic resonance in cardiac resynchronization therapy.

Authors:  Francisco Leyva; Paul W X Foley
Journal:  Heart Fail Rev       Date:  2011-05       Impact factor: 4.214

6.  Japan Implantable Devices in Coronary Artery Disease (JID-CAD) study design.

Authors:  Akihiko Shimizu; Takeshi Mitsuhashi; Takashi Nitta; Hideo Mitamura; Takashi Kurita; Haruhiko Abe; Yuji Nakazato; Naokata Sumitomo; Kazushige Kadota; Kazuo Kimura; Ken Okumura
Journal:  J Arrhythm       Date:  2014-09-12

7.  Myocardial denervation coincides with scar heterogeneity in ischemic cardiomyopathy: A PET and CMR study.

Authors:  Stefan de Haan; Mischa T Rijnierse; Hendrik J Harms; Hein J Verberne; Adriaan A Lammertsma; Marc C Huisman; Albert D Windhorst; Albert C van Rossum; Cornelis P Allaart; Paul Knaapen
Journal:  J Nucl Cardiol       Date:  2015-11-09       Impact factor: 5.952

Review 8.  Arrhythmias in Patients ≥80 Years of Age: Pathophysiology, Management, and Outcomes.

Authors:  Anne B Curtis; Roshan Karki; Alexander Hattoum; Umesh C Sharma
Journal:  J Am Coll Cardiol       Date:  2018-05-08       Impact factor: 24.094

Review 9.  ICD programming to reduce shocks and improve outcomes.

Authors:  Valentina Kutyifa; Wojciech Zareba; Arthur J Moss
Journal:  Curr Cardiol Rep       Date:  2014       Impact factor: 2.931

10.  Reduction of the inappropriate ICD therapies by implementing a new fuzzy logic-based diagnostic algorithm.

Authors:  Michał Lewandowski; Andrzej Przybylski; Wiesław Kuźmicz; Hanna Szwed
Journal:  Ann Noninvasive Electrocardiol       Date:  2013-09       Impact factor: 1.468

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.