Simulation of pulmonary ventilation and its control by negative feedback.

J Dolensek1, F Runovc, M Kordas.   

Abstract

The equivalent electronic circuit developed to simulate pulmonary ventilation is upgraded to incorporate homeostasis, i.e. a negative feedback loop. The latter can be made either inactive or active. In the former condition, only the immediate consequence of a disturbance shows up. In the latter condition, however, full homeostatic--sometimes very complex--response can be studied. The effects of three types of disturbances are studied in both conditions (i.e. open loop, closed loop): increased CO2 production, temporary apnoea, and of bronchoconstriction (in the whole lung or only in part of the lung). The effect of increased CO2 production is increase in pulmonary ventilation and increase in pCO2. The latter strongly depends on the feedback response. Temporary apnoea results in a transient increase in pCO2. However, if the time constant of the feedback loop is large enough, this type of disturbance results in a maintained periodic, Cheyne-Stokes-type breathing. Bronchoconstriction in 100% of the lung results in a decrease in tidal volume. If homeostasis is active this decrease is compensated by an increase in the inspiratory effort. However, if bronchoconstriction occurs only in 50% of the lung, inspiratory effort is greatly changed through inter-alveolar elastic interactions, giving rise to the so-called pendelluft.

Entities:  

Mesh:

Year:  2005        PMID: 15582629     DOI: 10.1016/j.compbiomed.2004.02.002

Source DB:  PubMed          Journal:  Comput Biol Med        ISSN: 0010-4825            Impact factor:   4.589


  1 in total

1.  Pressure dynamic characteristics of pressure controlled ventilation system of a lung simulator.

Authors:  Yan Shi; Shuai Ren; Maolin Cai; Weiqing Xu; Qiyou Deng
Journal:  Comput Math Methods Med       Date:  2014-08-13       Impact factor: 2.238

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.