Clamping of the renal artery in laparoscopic partial nephrectomy: an old device for a new technique.

A Rosales1, J Salvador, N De Graeve, O Angerri, H Villavicencio.   

Abstract

OBJECTIVE: We describe our experience with the transient clamping of the renal artery during laparoscopic partial nephrectomy for renal cancer with a double loop clamping device, inspired by the Rumel tourniquet. The silastic rubber loop is positioned around the renal artery and clinched, thus achieving arterial occlusion.
METHODS: From November 2002 until July 2004, fourteen consecutive patients (mean age of 58 +/- 11.6 years) underwent laparoscopic transperitoneal partial nephrectomy using the silastic rubber clamping device, eight of them on the right side and six on the left side. Hemorrhage of the renal defect was controlled with bipolar electrocoagulation, argon beam coagulation, laparoscopic sutures, surgical and fibrin glue.
RESULTS: : The mean surgical time was 198.92 +/- 39.95 min for a mean tumour size of 2.9 +/- 2.32 cm and a mean blood loss of 104.57 +/- 77.69 ml. The clamping device was easily and successfully positioned around the renal artery in 2.05 +/- 0.45 min and the mean warm ischemic time was 25.21 +/- 6.07 min.
CONCLUSIONS: The clamping device procures successful atraumatic occlusion of the renal artery during laparoscopic partial nephrectomy without the need for an additional port. As such, it could be considered as an alternative for the laparoscopic bulldog and Satinsky clamp.

Entities:  

Mesh:

Year:  2005        PMID: 15582256     DOI: 10.1016/j.eururo.2004.08.021

Source DB:  PubMed          Journal:  Eur Urol        ISSN: 0302-2838            Impact factor:   20.096


  4 in total

Review 1.  A review of methods for hemostasis and renorrhaphy after laparoscopic and robot-assisted laparoscopic partial nephrectomy.

Authors:  Rajan Ramanathan; Raymond J Leveillee
Journal:  Curr Urol Rep       Date:  2010-05       Impact factor: 3.092

2.  A Feasible Technique for Transient Vascular Occlusion by Using a Vessel Loop and Hem-o-Lok Clips in Laparoscopic Partial Nephrectomy.

Authors:  Yoon Hyung Lee; Joon Beom Kwon; Sung Ryong Cho; Jae Soo Kim
Journal:  Korean J Urol       Date:  2011-08-22

3.  Laparoscopic partial nephrectomy: Technical considerations and an update.

Authors:  Jose L Dominguez-Escrig; Nikhil Vasdev; Anna O'Riordon; Naeem Soomro
Journal:  J Minim Access Surg       Date:  2011-10       Impact factor: 1.407

4.  Impact of "non-clamping technique" on intra- and postoperative course after laparoscopic partial nephrectomy.

Authors:  Piotr Petrasz; Marcin Słojewski; Andrzej Sikorski
Journal:  Wideochir Inne Tech Maloinwazyjne       Date:  2012-09-29       Impact factor: 1.195

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.