Literature DB >> 1558112

Ultrasound biomicroscopy in plateau iris syndrome.

C J Pavlin1, R Ritch, F S Foster.   

Abstract

Ultrasound biomicroscopy is a new technique that uses high-frequency ultrasound (50 to 100 MHz) to produce images of the entire anterior segment at high resolution (20 to 50 microns). The iridocorneal angle, iris, ciliary body, and posterior chamber can be imaged in detail and the dimensions and anatomic relationships of these structures determined. Plateau iris syndrome is a condition in which the angle remains appositionally closed or occludable after iridectomy for angle-closure glaucoma. How the iris remains in a position that allows it to occlude the angle has been uncertain. We performed ultrasound biomicroscopy eye examinations on eight patients with clinically diagnosed plateau iris syndrome. In all the patients, ciliary processes were situated anteriorly compared to the position in normal subjects and in patients with angle closure caused by pupillary block. The ciliary processes provide structural support beneath the peripheral iris, preventing the iris root from falling away from the trabecular meshwork after iridectomy.

Entities:  

Mesh:

Year:  1992        PMID: 1558112     DOI: 10.1016/s0002-9394(14)76160-4

Source DB:  PubMed          Journal:  Am J Ophthalmol        ISSN: 0002-9394            Impact factor:   5.258


  36 in total

1.  Ultrasound biomicroscopic study of sclerotomy sites after implantation of sustained release drug devices.

Authors:  S Kunimatsu; Y Fujino; Y Nagata; K Ono; M Mochizuki; J Numaga; H Kawashima; M Araie
Journal:  Br J Ophthalmol       Date:  2002-08       Impact factor: 4.638

2.  [Reproducibility of goniometry with slitlamp-adapted optical coherence tomography].

Authors:  A Karandish; C Wirbelauer; H Häberle; D T Pham
Journal:  Ophthalmologe       Date:  2004-06       Impact factor: 1.059

3.  [OCT-goniometry before and after iridotomy in angle-closure glaucoma].

Authors:  A Karandish; C Wirbelauer; H Häberle; D T Pham
Journal:  Ophthalmologe       Date:  2006-01       Impact factor: 1.059

4.  Anterior segment imaging for glaucoma: OCT or UBM?

Authors:  Hiroshi Ishikawa
Journal:  Br J Ophthalmol       Date:  2007-11       Impact factor: 4.638

5.  A case of iridoschisis associated with plateau iris configuration.

Authors:  Chiharu Shima; Yasumasa Otori; Atsuya Miki; Yasuo Tano
Journal:  Jpn J Ophthalmol       Date:  2007-10-05       Impact factor: 2.447

6.  Ultrasound biomicroscopic measurement of anterior chamber angle in premature infants.

Authors:  H Kobayashi; J Kiryu; K Kobayashi; T Kondo
Journal:  Br J Ophthalmol       Date:  1997-06       Impact factor: 4.638

7.  Light-dark changes in iris thickness and anterior chamber angle width in eyes with occludable angles.

Authors:  Fumitaka Hirose; Masayuki Hata; Shin-ichiro Ito; Takaaki Matsuki; Yasuo Kurimoto
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2013-05-21       Impact factor: 3.117

8.  Ultrasound biomicroscopic measurement of development of anterior chamber angle.

Authors:  H Kobayashi; H Ono; J Kiryu; K Kobayashi; T Kondo
Journal:  Br J Ophthalmol       Date:  1999-05       Impact factor: 4.638

9.  Pilocarpine induces an increase in the anterior chamber angular width in eyes with narrow angles.

Authors:  H Kobayashi; K Kobayashi; J Kiryu; T Kondo
Journal:  Br J Ophthalmol       Date:  1999-05       Impact factor: 4.638

10.  Argon laser peripheral iridoplasty for plateau iris associated with iridociliary cysts: a case report.

Authors:  Ghee Soon Ang; Frank Bochmann; Augusto Azuara-Blanco
Journal:  Cases J       Date:  2008-12-02
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.