Literature DB >> 15578556

Cup inclination and serum concentration of cobalt and chromium after metal-on-metal total hip arthroplasty.

Wolfram Brodner1, Alexander Grübl, Rafael Jankovsky, Vanee Meisinger, Stephan Lehr, Florian Gottsauner-Wolf.   

Abstract

We investigated whether cup inclination influences serum levels of cobalt and chromium after metal-on-metal total hip arthroplasty. Out of a consecutive series, 3 groups of 20 patients each were established according to their cup inclination: greatest inclination (55 degrees -63 degrees, mean 58 degrees), intermediate inclination (44 degrees -46 degrees, mean 45 degrees), and smallest inclination (23 degrees -37 degrees, mean 33 degrees). We did not detect any statistically significant difference of serum cobalt (P = .23) or serum chromium (P = .13) levels between the 3 groups applying the Kruskal Wallis test. However, 3 patients with cup inclinations of 58 degrees , 63 degrees , and 61 degrees exhibited 9.8-53.6-fold elevated cobalt and 9.5-30.5-fold elevated chromium levels when compared with the median concentrations of this trial. We therefore recommend accurate cup placement also for metal-on-metal articulations.

Entities:  

Mesh:

Substances:

Year:  2004        PMID: 15578556     DOI: 10.1016/j.arth.2004.09.003

Source DB:  PubMed          Journal:  J Arthroplasty        ISSN: 0883-5403            Impact factor:   4.757


  25 in total

1.  Low incidence of groin pain and early failure with large metal articulation total hip arthroplasty.

Authors:  John B Meding; Lindsey K Meding; E Michael Keating; Michael E Berend
Journal:  Clin Orthop Relat Res       Date:  2012-02       Impact factor: 4.176

2.  Intraoperative radiographs for placing acetabular components in hip resurfacing arthroplasty.

Authors:  Thomas P Gross; Fei Liu; Lee Webb
Journal:  Clin Orthop Relat Res       Date:  2011-06       Impact factor: 4.176

3.  Edge-loading severity as a function of cup lip radius in metal-on-metal total hips--a finite element analysis.

Authors:  Jacob M Elkins; Karen M Kruger; Douglas R Pedersen; John J Callaghan; Thomas D Brown
Journal:  J Orthop Res       Date:  2011-08-02       Impact factor: 3.494

4.  [Reasons for failure of hip resurfacing implants. A failure analysis based on 250 revision specimens].

Authors:  M M Morlock; N Bishop; F Stahmer; J Zustin; G Sauter; M Hahn; M Krause; W Rüther; M Amling
Journal:  Orthopade       Date:  2008-07       Impact factor: 1.087

5.  The learning curve for adopting hip resurfacing among hip specialists.

Authors:  Ryan M Nunley; Jinjun Zhu; Peter J Brooks; C Anderson Engh; Stephen J Raterman; John S Rogerson; Robert L Barrack
Journal:  Clin Orthop Relat Res       Date:  2010-02       Impact factor: 4.176

6.  Metal-on-metal: history, state of the art (2010).

Authors:  Philippe Triclot
Journal:  Int Orthop       Date:  2011-01-14       Impact factor: 3.075

7.  Trunnion corrosion as a cause of recurrent pseudotumor.

Authors:  Alejandro D Zylberberg; Isabelle Catelas; Luca Gala; Paul R Kim
Journal:  HSS J       Date:  2015-01-30

8.  2008 John Charnley award: metal ion levels after metal-on-metal total hip arthroplasty: a randomized trial.

Authors:  C Anderson Engh; Steven J MacDonald; Supatra Sritulanondha; Abigail Thompson; Douglas Naudie; Charles A Engh
Journal:  Clin Orthop Relat Res       Date:  2008-10-15       Impact factor: 4.176

9.  Metal-on-Metal Total Hip Resurfacing Arthroplasty: An Evidence-Based Analysis.

Authors: 
Journal:  Ont Health Technol Assess Ser       Date:  2006-02-01

Review 10.  Navigated cup implantation in hip arthroplasty.

Authors:  Johannes Beckmann; Dirk Stengel; Markus Tingart; Jürgen Götz; Joachim Grifka; Christian Lüring
Journal:  Acta Orthop       Date:  2009-10       Impact factor: 3.717

View more