Literature DB >> 15577798

A comparison of the results of monolayer versus smear cytopreparatory techniques for fine-needle aspiration in 100 consecutive patients undergoing thyroidectomy: a surgeon's perspective.

Robert L Witt1.   

Abstract

OBJECTIVE: To compare thyroid fine-needle aspiration (FNA) using monolayer (MT) versus conventional smear (CS) cytopreparatory techniques with final histology. STUDY
DESIGN: Retrospective review of 100 consecutive thyroidectomies. Setting Tertiary care university affiliated medical center.
RESULTS: 26% of MT aspirates were inadequate compared with 3% of CS aspirates (P < 0.05). The negative predictive values for MT and CS were 86% and 100%, respectively. The positive predictive values for MT and CS were 69% and 90%, respectively.
CONCLUSIONS: Fewer inadequate specimens will be obtained with CS than with MT. A clinician performing FNA can obtain adequate specimens at a rate comparable to that of a hospital-based cytopathologist. SIGNIFICANCE: CS provides greater assurance to the patient and the surgeon that a thyroid nodule with a FNA interpreted as benign can be observed. A higher percentage of patients with malignant tumor will receive thyroidectomy with the use of CS technique for FNA. EBM RATING: B-3.

Entities:  

Mesh:

Year:  2004        PMID: 15577798     DOI: 10.1016/j.otohns.2004.07.004

Source DB:  PubMed          Journal:  Otolaryngol Head Neck Surg        ISSN: 0194-5998            Impact factor:   3.497