Literature DB >> 15577467

Highly cross-linked, electron-beam-irradiated, melted polyethylene: some pros.

William H Harris1.   

Abstract

Extensive new evidence generated within the past the year provides strong support for the use of electron-beam highly cross-linked, subsequently melted ultra-high molecular weight polyethylene in total hip replacement arthroplasty. In terms of wear reduction, three studies involving three different demographic groups and two different measurement techniques have found that the femoral head penetration with this type of polyethylene after bedding in has finished taking place is less than 10 micra per year. This wear rate is similar to the wear rate of metal-on-metal and ceramic-on-ceramic articulations. Retrieval specimens up to 3 years after insertion confirmed the minimal wear by exhibiting persisting machine marks throughout the inside diameter of the liner. Extensive studies show no evidence of oxidation, confirming the absence of residual free radicals. No evidence of fatigue failure exists except three known cases out of 150,000, in which malposition of the acetabular component produced abnormally high contact stresses on unsupported polyethylene. The in vivo wear, oxidation resistance, and mechanical properties of this alternative bearing material are excellent, with in vivo durations now exceeding five years. The other major advantages over hard-on-hard bearings including familiarity, adaptability, forgiveness, and cost seem to be compelling.

Entities:  

Mesh:

Substances:

Year:  2004        PMID: 15577467     DOI: 10.1097/01.blo.0000149827.55160.42

Source DB:  PubMed          Journal:  Clin Orthop Relat Res        ISSN: 0009-921X            Impact factor:   4.176


  7 in total

1.  Mid-term results of large diameter heads on cross-linked polyethylene liners in total hip replacement.

Authors:  Bhavesh Sachde; Nikunj D Maru
Journal:  J Clin Orthop Trauma       Date:  2012-10-17

Review 2.  Strategies for head and inlay exchange in revision hip arthroplasty.

Authors:  Martin Pospischill; Karl Knahr
Journal:  Int Orthop       Date:  2010-11-19       Impact factor: 3.075

3.  Modular cementless cup for total hip arthroplasty: results at 4-year follow-up.

Authors:  Alessandro Bistolfi; Giuseppe Massazza; Federica Rosso; Stefano Ventura; Francesco Lagalla; Maurizio Crova
Journal:  Musculoskelet Surg       Date:  2012-01-06

4.  Is there any difference in survivorship of total hip arthroplasty with different bearing surfaces? A systematic review and network meta-analysis.

Authors:  Si Yin; Dangfeng Zhang; Hui Du; Heng Du; Zhanhai Yin; Yusheng Qiu
Journal:  Int J Clin Exp Med       Date:  2015-11-15

5.  Preclinical Evaluation of a Novel 3D-Printed Movable Lumbar Vertebral Complex for Replacement: In Vivo and Biomechanical Evaluation of Goat Model.

Authors:  Feng Zhang; Jiantao Liu; Xijing He; Rui Wang; Teng Lu; Ting Zhang; Zhiyu Liu
Journal:  Biomed Res Int       Date:  2021-12-10       Impact factor: 3.411

6.  Vitamin E-Enhanced Liners in Primary Total Hip Arthroplasty: A Systematic Review and Meta-Analysis.

Authors:  Qian-Yue Cheng; Bin-Fei Zhang; Peng-Fei Wen; Jun Wang; Lin-Jie Hao; Tao Wang; Hui-Guang Cheng; Ya-Kang Wang; Jian-Bin Guo; Yu-Min Zhang
Journal:  Biomed Res Int       Date:  2021-12-06       Impact factor: 3.411

7.  UHMWPE for arthroplasty: past or future?

Authors:  Elena Maria Brach Del Prever; Alessandro Bistolfi; Pierangiola Bracco; Luigi Costa
Journal:  J Orthop Traumatol       Date:  2008-12-24
  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.