Failure analysis of explanted sternal wires.

Chun-Ming Shih1, Yea-Yang Su, Shing-Jong Lin, Chun-Che Shih.   

Abstract

To classify and understand the mechanisms of surface damages and fracture mechanisms of sternal wires, explanted stainless steel sternal wires were collected from patients with sternal dehiscence following open-heart surgery. Surface alterations and fractured ends of sternal wires were examined and analyzed. Eighty fractured wires extracted from 25 patients from January 1999 to December 2003, with mean implantation interval of 55+/-149 days (range 5-729 days) after cardiac surgery, were studied by various techniques. The extracted wires were cleaned and the fibrotic tissues were removed. Irregularities and fractured ends were assayed by a scanning electron microscopy. After stereomicroscopy and documentation, the explants were cleaned with 1% sodium hypochlorite to remove the blood and tissues and was followed by cleaned with deionized water and alcohol. The explants were examined by stereomicroscopy, and irregularities on surface and fracture surfaces of sternal wires were assayed by scanning electron microscopy, energy dispersive X-ray analysis (EDAX) and X-ray mapping. The explants with surrounding fibrotic tissue were stained and examined with stereomicroscopy and transmission electronic microscopy. Corrosion pits were found on the surface of explanted sternal wires. EDAX and X-ray mapping examinations revealed diminution of nickel concentration in the severely corroded pits on sternal wires. A feature of transgranular cracking was observed for stress corrosion cracking and striation character for typical corrosion fatigue was also identified. TEM examination of tissue showed the metallic particles in phagolysosomes of macrophages inside the surrounding sternal tissue. The synergic effect of hostile environment and the stress could be the precursors of failures for sternal wires.

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 15576179     DOI: 10.1016/j.biomaterials.2004.07.005

Source DB:  PubMed          Journal:  Biomaterials        ISSN: 0142-9612            Impact factor:   12.479


  3 in total

1.  Chest pain due to sternotomy wire suture in a patient with revascularized coronary heart disease.

Authors:  Bettina J Stuck; Rainer E Dabew; Hans-Joachim Schaefers; Michael Boehm
Journal:  Clin Res Cardiol       Date:  2006-09-28       Impact factor: 5.460

2.  Wire fracture in postoperative Nuss procedure: a problem that cannot be ignored.

Authors:  Yunxuan Zhang; Qiang Chen; Yarui Luo; Chenyu Sun; Meng Chen; Na Wu; Yimin Xie
Journal:  Transl Pediatr       Date:  2021-03

3.  Fatigue testing of three peristernal median sternotomy closure techniques.

Authors:  Cameron Wangsgard; David J Cohen; Lanny V Griffin
Journal:  J Cardiothorac Surg       Date:  2008-09-24       Impact factor: 1.637

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.