Literature DB >> 15574174

Incidence and risk factors of early venous thrombosis associated with permanent pacemaker leads.

Cornelis J van Rooden1, Sander G Molhoek, Frits R Rosendaal, Martin J Schalij, A Edo Meinders, Menno V Huisman.   

Abstract

INTRODUCTION: Pacemaker lead implantation can cause thrombosis, which can be associated with serious local morbidity and complicated by pulmonary embolism. Few reliable estimates of the incidence of thrombosis have been reported. The contribution of established risk factors to venous thrombosis in patients with implanted pacemaker leads is unknown. METHODS AND
RESULTS: One hundred forty-five consecutive patients n = 145) underwent routine clinical and Doppler ultrasound evaluation for thrombosis before and 3, 6, and 12 months after lead implantation. Established risk factors for venous thrombosis were assessed in detail for all patients. Clinical outcome, including clinically manifest thrombosis, pulmonary embolism, associated pacemaker lead infection, complicated reinterventions, and death, was evaluated. Thrombosis was observed in 34 (23%) of 145 patients. Thrombosis did not cause any signs or symptoms in 31 patients but resulted in overt clinical symptoms in 3 patients. The absence of anticoagulant therapy, use of hormone therapy, and a personal history of venous thrombosis were associated with an increased risk of thrombosis. The risk of thrombosis increased in the presence of multiple pacemaker leads compared to a single lead.
CONCLUSION: Established risk factors for venous thrombosis and the presence of multiple pacemaker leads contribute substantially to the occurrence of thrombosis associated with permanent pacemaker leads. Risk factor assessment prior to implantation may be useful for identifying patients at risk for thrombotic complications. Preventive management in these patients is warranted.

Entities:  

Mesh:

Year:  2004        PMID: 15574174     DOI: 10.1046/j.1540-8167.2004.04081.x

Source DB:  PubMed          Journal:  J Cardiovasc Electrophysiol        ISSN: 1045-3873


  29 in total

1.  Cardiac implantable electronic devices in end-stage renal disease patients: preservation of central venous circulation.

Authors:  Gustavo Lopera; Gerald A Beathard; Jose Exaire; Roger Carrillo
Journal:  J Interv Card Electrophysiol       Date:  2012-06       Impact factor: 1.900

2.  Incidence and predictors of subclavian vein obstruction following biventricular device implantation.

Authors:  Serkan Bulur; Ahmet Vural; Mehmet Yazıcı; Gökhan Ertaş; Hakan Özhan; Dilek Ural
Journal:  J Interv Card Electrophysiol       Date:  2010-10-02       Impact factor: 1.900

Review 3.  [Strategies for the avoidance and treatment of complications during pacemaker implantation].

Authors:  C Kolb
Journal:  Herzschrittmacherther Elektrophysiol       Date:  2007-12

4.  Recombinant Tissue Plasminogen Activator in the Treatment of Neonates with Intracardiac and Great Vessels Thrombosis.

Authors:  Milad El-Segaier; Muhammad A Khan; Zaheer Ullah Khan; Tarek Momenah; Mohammed Omar Galal
Journal:  Pediatr Cardiol       Date:  2015-05-21       Impact factor: 1.655

Review 5.  Guidance for the treatment of deep vein thrombosis and pulmonary embolism.

Authors:  Michael B Streiff; Giancarlo Agnelli; Jean M Connors; Mark Crowther; Sabine Eichinger; Renato Lopes; Robert D McBane; Stephan Moll; Jack Ansell
Journal:  J Thromb Thrombolysis       Date:  2016-01       Impact factor: 2.300

6.  Consequences of Retained Defibrillator and Pacemaker Leads After Heart Transplantation-An Underrecognized Problem.

Authors:  Luise Holzhauser; Teruhiko Imamura; Hemal M Nayak; Nitasha Sarswat; Gene Kim; Jayant Raikhelkar; Sara Kalantari; Amit Patel; David Onsager; Tae Song; Takeyoshi Ota; Valluvan Jeevanandam; Gabriel Sayer; Nir Uriel
Journal:  J Card Fail       Date:  2018-01-08       Impact factor: 5.712

7.  Implanted endocardial lead characteristics and risk of stroke or transient ischemic attack.

Authors:  Vaibhav R Vaidya; Christopher V DeSimone; Samuel J Asirvatham; Vishnu M Chandra; Amit Noheria; David O Hodge; Joshua P Slusser; Alejandro A Rabinstein; Paul A Friedman
Journal:  J Interv Card Electrophysiol       Date:  2014-04-27       Impact factor: 1.900

8.  Pulmonary embolism in patients with transvenous cardiac implantable electronic device leads.

Authors:  Amit Noheria; Shiva P Ponamgi; Christopher V Desimone; Vaibhav R Vaidya; Christopher A Aakre; Elisa Ebrille; Tiffany Hu; David O Hodge; Joshua P Slusser; Naser M Ammash; Charles J Bruce; Alejandro A Rabinstein; Paul A Friedman; Samuel J Asirvatham
Journal:  Europace       Date:  2015-03-12       Impact factor: 5.214

9.  A streamlined technique of trans-septal endocardial left ventricular lead placement.

Authors:  Ernest W Lau
Journal:  J Interv Card Electrophysiol       Date:  2009-04-22       Impact factor: 1.900

10.  Pacemaker induced superior vena cava syndrome: a case report.

Authors:  Egambaram Senthilvel; Aphrodite Papadakis; Vikas Jain; Julia Bruner
Journal:  Cases J       Date:  2009-07-29
View more