BACKGROUND: A new bone preparation technique, using smooth tamps for bone compaction, has increased crucial initial implant stability. However, preparing the femur with bulky smooth tamps, which from size to size increases the same amount in anterior to posterior as in lateral to medial dimensions, has increased the risk of a femoral fracture. This study examined whether compaction also involved an increased femoral fracture risk when using newly developed smooth tamps with a slim anterior to posterior dimension.
METHODS: One femur in each pair of 10 cadaver femurs was prepared by the compaction technique using cylindrical reamers and smooth tamps. The contralateral femur was conventionally prepared with conical reamers and toothed rasps. The tamps and rasps differed in design as a proximal lateral tip was only present on the smooth tamps. Using a standardized test protocol, the instruments were driven into the femoral canal in controlled manner by a drop tower.
FINDINGS: At maximum test conditions, five of 10 femurs in the compaction group had fractured, as compared with no fractures in the rasping group. All fractures were longitudinal fissures in the greater trochanter, and these fissures were associated with the extended proximal lateral tip of the tamps.
INTERPRETATION: Since the lateral fractures in the compaction group were associated with the extended proximal lateral tip of the tamps, it seems that fracture rates are influenced by instrumentation design. Therefore adequate pre-clinical evaluation is warranted prior to the introduction of new implantation techniques.

Entities:  

Mesh:

Year:  2005        PMID: 15567540     DOI: 10.1016/j.clinbiomech.2004.08.003

Source DB:  PubMed          Journal:  Clin Biomech (Bristol, Avon)        ISSN: 0268-0033            Impact factor:   2.063


  2 in total

1.  Preparation of the femoral bone cavity in cementless stems: broaching versus compaction.

Authors:  Mette H Hjorth; Maiken Stilling; Kjeld Søballe; Poul Torben Nielsen; Poul H Christensen; Søren Kold
Journal:  Acta Orthop       Date:  2016-10-19       Impact factor: 3.717

2.  Variability in Femoral Preparation and Implantation Between Surgeons Using Manual and Powered Impaction in Total Hip Arthroplasty.

Authors:  Tobias Konow; Johanna Bätz; David Beverland; Tim Board; Frank Lampe; Klaus Püschel; Michael M Morlock
Journal:  Arthroplast Today       Date:  2022-01-20
  2 in total