Literature DB >> 15562488

Interscan registration using navigator echoes.

Edward Brian Welch1, Armando Manduca, Roger C Grimm, Clifford R Jack.   

Abstract

A common problem in clinical MRI is anatomic misalignment of imaging slices across successive examinations. This unnecessarily complicates the radiologic assessment of anatomic change over time on serial MRI studies. To address this problem, spherical navigator echoes, which can detect rigid body motion in all six degrees of freedom, were used to guide spatial location and orientation adjustments to an exam prescription to match the reference frame of images acquired in an earlier exam. An initial linear navigator echo is also necessary to effect coarse Z translation adjustments prior to fine six degrees of freedom adjustment with a spherical navigator echo. Results of this technique are presented for head image volumes of five volunteers. Each volunteer was imaged on two scanners. In all cases, the reference frame adjustments provided by the navigator echoes substantially improved the alignment of the latter exam and performed well compared to retrospective image-based registration. (c) 2004 Wiley-Liss, Inc.

Mesh:

Year:  2004        PMID: 15562488     DOI: 10.1002/mrm.20275

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  6 in total

1.  Atlas-based multichannel monitoring of functional MRI signals in real-time: automated approach.

Authors:  Jong-Hwan Lee; Heather M O'Leary; Hyunwook Park; Ferenc A Jolesz; Seung-Schik Yoo
Journal:  Hum Brain Mapp       Date:  2008-02       Impact factor: 5.038

2.  Fast prospective registration of in vivo MR images of trabecular bone microstructure in longitudinal studies.

Authors:  Chamith S Rajapakse; Jeremy F Magland; Felix W Wehrli
Journal:  Magn Reson Med       Date:  2008-05       Impact factor: 4.668

3.  Automatic voxel positioning for MRS at 7 T.

Authors:  Weiqiang Dou; Oliver Speck; Thomas Benner; Jörn Kaufmann; Meng Li; Kai Zhong; Martin Walter
Journal:  MAGMA       Date:  2014-11-20       Impact factor: 2.310

4.  Reproducibility of scan prescription in follow-up brain MRI: manual versus automatic determination.

Authors:  Shinya Kojima; Masami Hirata; Hiroyuki Shinohara; Eiko Ueno
Journal:  Radiol Phys Technol       Date:  2013-04-11

5.  Automated Voxel Placement: A Linux-based Suite of Tools for Accurate and Reliable Single Voxel Coregistration.

Authors:  Eric A Woodcock; Muzamil Arshad; Dalal Khatib; Jeffrey A Stanley
Journal:  J Neuroimaging Psychiatry Neurol       Date:  2018-02-08

6.  Correction of inter-scan motion artifacts in quantitative R1 mapping by accounting for receive coil sensitivity effects.

Authors:  Daniel Papp; Martina F Callaghan; Heiko Meyer; Craig Buckley; Nikolaus Weiskopf
Journal:  Magn Reson Med       Date:  2015-11-26       Impact factor: 4.668

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.