The use of a liposomal paramagnetic agent with a T(1)-relaxivity that increases markedly at temperatures above the phase transition temperature (T(m)) of the liposomal membrane was evaluated during magnetic resonance imaging (MRI) guided hyperthermia ablation. A neodymium-yttrium aluminum garnet (Nd-YAG) laser unit and a radiofrequency ablation system were used for tissue ablation in eight rabbit livers in vivo. One ablation was made in each animal prior to administration of the liposomal agent. Liposomes with a T(m) of 57 degrees C containing gadodiamide (GdDTPA-BMA) were injected iv, and two additional ablations were performed. T(1)-weighted scans were performed in heated tissue, after tissue temperature had normalized, and 15-20 min after normalization of tissue temperature. Increase in signal intensity (DeltaSI) for ablations prior to injection of the agent was 13.0% (SD = 5.7) for the laser group and 9.1% (SD = 7.9) for the radiofrequency group. Signal intensity after administration of the agent unrelated to heating was not statistically significant (DeltaSI = 1.4%, P = 0.35). For ablations made after injection of the agent, a significant increase was found in the laser (DeltaSI = 34.5%, SD = 11.9) and radiofrequency group (DeltaSI = 21.6%, SD = 22.7). The persistent signal enhancement found in areas exposed to a temperature above the threshold temperature above T(m) allows thermal monitoring of MRI guided thermal ablation. (c) 2004 Wiley-Liss, Inc.

Entities:  

Mesh:

Substances:

Year:  2004        PMID: 15562487     DOI: 10.1002/mrm.20289

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  10 in total

1.  Six-coordinate Iron(II) and Cobalt(II) paraSHIFT Agents for Measuring Temperature by Magnetic Resonance Spectroscopy.

Authors:  Pavel B Tsitovich; Jordan M Cox; Jason B Benedict; Janet R Morrow
Journal:  Inorg Chem       Date:  2015-12-30       Impact factor: 5.165

Review 2.  MR thermometry.

Authors:  Viola Rieke; Kim Butts Pauly
Journal:  J Magn Reson Imaging       Date:  2008-02       Impact factor: 4.813

Review 3.  Macromolecules, dendrimers, and nanomaterials in magnetic resonance imaging: the interplay between size, function, and pharmacokinetics.

Authors:  Aaron Joseph L Villaraza; Ambika Bumb; Martin W Brechbiel
Journal:  Chem Rev       Date:  2010-05-12       Impact factor: 60.622

4.  Formulation and characterisation of magnetic resonance imageable thermally sensitive liposomes for use with magnetic resonance-guided high intensity focused ultrasound.

Authors:  Ayele H Negussie; Pavel S Yarmolenko; Ari Partanen; Ashish Ranjan; Genevieve Jacobs; David Woods; Henry Bryant; David Thomasson; Mark W Dewhirst; Bradford J Wood; Matthew R Dreher
Journal:  Int J Hyperthermia       Date:  2011       Impact factor: 3.914

Review 5.  Imaging-based internal body temperature measurements: The journal Temperature toolbox.

Authors:  Juho Raiko; Kalle Koskensalo; Teija Sainio
Journal:  Temperature (Austin)       Date:  2020-05-29

6.  Combination radiofrequency (RF) ablation and IV liposomal heat shock protein suppression: reduced tumor growth and increased animal endpoint survival in a small animal tumor model.

Authors:  Wei Yang; Muneeb Ahmed; Beenish Tasawwar; Tatynana Levchenko; Rupa R Sawant; Vladimir Torchilin; S Nahum Goldberg
Journal:  J Control Release       Date:  2011-12-30       Impact factor: 9.776

7.  Radiofrequency ablation combined with liposomal quercetin to increase tumour destruction by modulation of heat shock protein production in a small animal model.

Authors:  Wei Yang; Muneeb Ahmed; Beenish Tasawwar; Tatyana Levchenko; Rupa R Sawant; Michael Collins; Sabina Signoretti; Vladimir Torchilin; S Nahum Goldberg
Journal:  Int J Hyperthermia       Date:  2011       Impact factor: 3.914

8.  Polymer platforms for drug delivery and biomedical imaging.

Authors:  Zheng-Rong Lu; Furong Ye; Anagha Vaidya
Journal:  J Control Release       Date:  2007-06-27       Impact factor: 9.776

Review 9.  Theoretical modeling for radiofrequency ablation: state-of-the-art and challenges for the future.

Authors:  Enrique J Berjano
Journal:  Biomed Eng Online       Date:  2006-04-18       Impact factor: 2.819

10.  Ferromagnetic particles as magnetic resonance imaging temperature sensors.

Authors:  J H Hankiewicz; Z Celinski; K F Stupic; N R Anderson; R E Camley
Journal:  Nat Commun       Date:  2016-08-09       Impact factor: 14.919

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.