Literature DB >> 15561022

Outcomes after usage of a quality initiative program for off-pump coronary artery bypass surgery: a comparison with on-pump surgery.

Sherif R Gobran1, Scott Goldman, Francis Ferdinand, Mary Ann Wertan, Candace Trace, Gary L Grunkemeier, Yingxing Wu, Francis P Sutter.   

Abstract

BACKGROUND: Off-pump coronary artery bypass (OPCAB) may be associated with improved outcomes when compared with on-pump coronary artery bypass. This study evaluates the use of a system for access and stabilization (SAS) with a coronary stabilizer as well as a clinical effectiveness quality initiative (CEQI) process regarding outcomes. This included the development of an expanded heart care team as well as standardization and refinement of perioperative care at The Lankenau Hospital (TLH). Our aim was to evaluate morbidity and mortality of on-pump coronary artery bypass grafting (CABG) compared with OPCAB surgery using SAS in addition to a CEQI initiative.
METHODS: A retrospective consecutive cohort study using the Society of Thoracic Surgery (STS) National Database was conducted. Three cohorts were analyzed: pre-SAS (December 1, 1999-August 31, 2000); use of SAS only (September 1, 2000-April 30, 2001), and the use of SAS + CEQI process (May 1, 2001-September 30, 2002). Morbidity and mortality for all on-pump CABG procedures performed over the time period of December 1, 1999-September 30, 2002 were compared with the SAS and SAS + CEQI groups only.
RESULTS: One-thousand two-hundred sixty-seven procedures were performed; 405 on-pump CABGs, 90 OPCABs pre-SAS, and 772 OPCABs with SAS, of which 552 were in the SAS + CEQI group. Statistically mortality was significantly lower in the SAS + CEQI vs the on-pump group (0.7% vs 3.0%, p < 0.01). The percentage of patients with prolonged ventilation was significantly lower statistically in the SAS + CEQI vs the on-pump group (4.2% vs 9.7%, p < 0.01). Statistically the length of stay was significantly lower in both SAS groups compared with the on-pump group (p < 0.01).
CONCLUSIONS: OPCAB surgery using SAS in conjunction with a CEQI initiative improves outcomes for patients compared with on-pump CABG surgery.

Entities:  

Mesh:

Year:  2004        PMID: 15561022     DOI: 10.1016/j.athoracsur.2004.05.084

Source DB:  PubMed          Journal:  Ann Thorac Surg        ISSN: 0003-4975            Impact factor:   4.330


  4 in total

1.  Does dual antibiotic prophylaxis better prevent surgical site infections in total joint arthroplasty?

Authors:  Amy Sewick; Amun Makani; Chia Wu; Judith O'Donnell; Keith D Baldwin; Gwo-Chin Lee
Journal:  Clin Orthop Relat Res       Date:  2012-10       Impact factor: 4.176

Review 2.  Off-pump coronary artery bypass grafting: Misperceptions and misconceptions.

Authors:  Shahzad G Raja; Umberto Benedetto
Journal:  World J Methodol       Date:  2014-03-26

Review 3.  We should ban the OPCAB approach in CABG, just as we should ban jetliners and bicycles, or maybe not!

Authors:  Paul Sergeant
Journal:  J Thorac Dis       Date:  2016-11       Impact factor: 2.895

4.  Effects of Cardiopulmonary Bypass on Mediastinal Drainage and the Use of Blood Products in the Intensive Care Unit in 60- to 80-Year-Old Patients Who Have Undergone Coronary Artery Bypass Grafting.

Authors:  Fatih Aygün; Mehmet Özülkü; Murat Günday
Journal:  Braz J Cardiovasc Surg       Date:  2015 Nov-Dec
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.