Literature DB >> 15560808

Bone level change at implant-supported fixed partial dentures with and without cantilever extension after 5 years in function.

Jan Wennström1, Jose Zurdo, Stig Karlsson, Annika Ekestubbe, Kerstin Gröndahl, Jan Lindhe.   

Abstract

OBJECTIVE: The aim of this study was to retrospectively analyze whether the inclusion of cantilever extensions increased the amount of marginal bone loss at free-standing, implant-supported, fixed partial dentures (FPDs) over a 5-year period of functional loading.
MATERIAL AND METHODS: The patient material comprised 45 periodontally treated, partially dentate patients with a total of 50 free-standing FPDs supported by implants of the Astra Tech System. Following FPD placement (baseline) the patients were enrolled in an individually designed supportive care program. A set of criteria was collected at baseline to characterize the FPDs. The primary outcome variable was change in peri-implant bone level from the time of FPD placement to the 5-year follow-up examination. The comparison between FPDs with and without cantilevers was performed at three levels: FPD level, implant level, and surface level. Bivariate analysis was performed by the use of the Mann-Whitney U-test and stepwise regression analysis was utilized to evaluate the potential influence of confounding factors on the change in peri-implant bone level.
RESULTS: The overall mean marginal bone loss for the implant-supported FPDs after 5 years in function was 0.4 mm (SD, 0.76). The bone level change at FPDs placed in the maxilla was significantly greater than that for FPDs in the mandible (0.6 versus 0.2 mm; p<0.05). No statistically significant differences were found with regard to peri-implant bone level change over the 5 years between FPDs with and without cantilevers at any of the levels of comparisons. The multivariate analysis revealed that the variables jaw of treatment and smoking had a significant influence on peri-implant bone level change on the FPD level, but not on the implant or surface levels. The model explained only 10% of the observed variance in the bone level change.
CONCLUSION: The study failed to demonstrate that the presence of cantilever extensions in an FPD had an effect on peri-implant bone loss.

Entities:  

Mesh:

Substances:

Year:  2004        PMID: 15560808     DOI: 10.1111/j.1600-051X.2004.00603.x

Source DB:  PubMed          Journal:  J Clin Periodontol        ISSN: 0303-6979            Impact factor:   8.728


  8 in total

Review 1.  Dental occlusion: modern concepts and their application in implant prosthodontics.

Authors:  Gunnar E Carlsson
Journal:  Odontology       Date:  2009-01-29       Impact factor: 2.634

2.  Radiological evaluation of the Cresco system in combination with Osseospeed implants: a preliminary 3-year report.

Authors:  N Baldini; M DE Sanctis; M C Cagidiaco; P Balleri; F Vignoletti; C Goracci; M Ferrari
Journal:  Oral Implantol (Rome)       Date:  2014-12-27

3.  Biomechanical consequences of progressive marginal bone loss around oral implants: a finite element stress analysis.

Authors:  Kivanc Akca; Murat Cavit Cehreli
Journal:  Med Biol Eng Comput       Date:  2006-06-10       Impact factor: 2.602

4.  Two short implants versus one short implant with a cantilever: 5-Year results of a randomized clinical trial.

Authors:  Daniel S Thoma; Karin Wolleb; Roman Schellenberg; Franz-Josef Strauss; Christoph H F Hämmerle; Ronald E Jung
Journal:  J Clin Periodontol       Date:  2021-09-22       Impact factor: 7.478

Review 5.  The Overall Survival, Complication-Free Survival, and Related Complications of Combined Tooth-Implant Fixed Partial Dentures: A Literature Review.

Authors:  Peter Borg; James Puryer; Lisa McNally; Dominic O'Sullivan
Journal:  Dent J (Basel)       Date:  2016-05-25

6.  Peri-Implant Behavior of Tissue Level Dental Implants with a Convergent Neck.

Authors:  Rubén Agustín-Panadero; Irene Bermúdez-Mulet; Lucía Fernández-Estevan; María Fernanda Solá-Ruíz; Rocío Marco-Pitarch; Marina García-Selva; Álvaro Zubizarreta-Macho; Raquel León-Martínez
Journal:  Int J Environ Res Public Health       Date:  2021-05-14       Impact factor: 3.390

7.  Peri-implant crestal bone loss: a putative mechanism.

Authors:  Yuko Ujiie; Reynaldo Todescan; John E Davies
Journal:  Int J Dent       Date:  2012-10-02

8.  Finite Element Analysis Generates an Increasing Interest in Dental Research: A Bibliometric Study.

Authors:  Abdoulaziz Diarra; Vagan Mushegyan; Adrien Naveau
Journal:  Open Dent J       Date:  2016-02-29
  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.