Literature DB >> 15558574

Three-dimensional MR angiography in imaging platinum alloy stents.

David W Trost1, Hong Lei Zhang, Martin R Prince, Priscilla A Winchester, Yi Wang, Richard Watts, Thomas A Sos.   

Abstract

PURPOSE: To evaluate visualization inside platinum stents with three-dimensional contrast-enhanced magnetic resonance angiography (CE-MRA).
MATERIALS AND METHODS: Breath-hold three-dimensional gadolinium (Gd) MRA was performed on 18 patients with 22 platinum stents in the renal (n = 18), celiac (n = 1), superior mesenteric (n = 1), and iliac (n = 2) arteries. Electronic calibers were used to measure the lumen diameter within the stent and just distal to the stent to calculate percent stenosis. MRA accuracy was determined from the difference between percent stenosis measured on MRA and digital subtracted angiography (DSA). The patients were imaged at flip angles of 45 degrees , 60 degrees , 75 degrees , 90 degrees , and 150 degrees .
RESULTS: MRA demonstrated the stent lumen in all of the patients, with a mean difference between MRA and DSA of 21%. For stents oriented parallel to B0 (iliac arteries) the difference was only 10%, as compared to 22% for stents perpendicular to B0. The flip angle with the best agreement between MRA and DSA was 75 degrees (16%).
CONCLUSION: The lumen of a platinum stent can be imaged with three-dimensional CE-MRA, although grading of restenosis has limited accuracy. The best results were obtained with a flip angle of 75 degrees and for stents in the iliac arteries parallel to B0. 2004 Wiley-Liss, Inc.

Entities:  

Mesh:

Substances:

Year:  2004        PMID: 15558574     DOI: 10.1002/jmri.20209

Source DB:  PubMed          Journal:  J Magn Reson Imaging        ISSN: 1053-1807            Impact factor:   4.813


  3 in total

Review 1.  Vascular imaging: the evolving role of the multidisciplinary team meeting in peripheral vascular disease.

Authors:  Andrew Christie; Giles Roditi
Journal:  Semin Intervent Radiol       Date:  2014-12       Impact factor: 1.513

2.  Optimization of MR Parameters of 3D TOF-MRA for Various Intracranial Stents at 3.0T MRI.

Authors:  Jin Woo Choi; Hong Gee Roh; Won-Jin Moon; Young Il Chun; Chung Hwan Kang
Journal:  Neurointervention       Date:  2011-08-31

3.  Usefulness of black-blood magnetic resonance angiography generated from vessel wall imaging after the stent-assisted treatment of intracranial arterial diseases.

Authors:  Miho Gomyo; Kazuhiro Tsuchiya; Shun Goto; Shinsuke Hosoi; Takahiro Tahara; Kenichi Yokoyama
Journal:  Neuroradiol J       Date:  2021-06-06
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.