Literature DB >> 15556818

Echocardiographic evaluation of patients receiving a new left ventricular assist device: the Impella recover 100.

Emanuele Catena1, Filippo Milazzo, Mario Merli, Roberto Paino, Andrea Garatti, Tiziano Colombo, Ettore Vitali.   

Abstract

UNLABELLED: The aim of this study was to suggest a protocol for serial echocardiographic evaluations in patients undergoing circulatory support by a new miniaturized electric axial pump, the Impella recover 100 (IR 100). IR 100 is implanted through the ascending aorta into the left ventricle drawing blood from the left ventricle to the aorta. METHODS AND
RESULTS: This protocol has been applied in eight patients receiving twelve IR 100 implants. Before implantation echocardiography was useful to rule out anatomic contraindications. During and after implantation echocardiography provided informations for correct positioning and evaluation of left ventricular filling necessary to optimize pump performance. During assistance it gave important informations to assess left and right ventricular function.
CONCLUSION: Echocardiography has pivotal role in IR 100 management before, during and after implantation.

Entities:  

Mesh:

Year:  2004        PMID: 15556818     DOI: 10.1016/j.euje.2004.03.008

Source DB:  PubMed          Journal:  Eur J Echocardiogr        ISSN: 1532-2114


  6 in total

1.  Impella 2.5.

Authors:  Daniel H Raess; David M Weber
Journal:  J Cardiovasc Transl Res       Date:  2009-04-02       Impact factor: 4.132

2.  Ventricular unloading with a miniature axial flow pump in combination with extracorporeal membrane oxygenation.

Authors:  Dirk Vlasselaers; Matthias Desmet; Lars Desmet; Bart Meyns; Joseph Dens
Journal:  Intensive Care Med       Date:  2006-01-24       Impact factor: 17.440

Review 3.  The use of echocardiographic indices in defining and assessing right ventricular systolic function in critical care research.

Authors:  Stephen J Huang; Marek Nalos; Louise Smith; Arvind Rajamani; Anthony S McLean
Journal:  Intensive Care Med       Date:  2018-05-22       Impact factor: 17.440

4.  Focused review on transthoracic echocardiographic assessment of patients with continuous axial left ventricular assist devices.

Authors:  Yan Topilsky; Simon Maltais; Jae K Oh; Fawn W Atchison; Louis P Perrault; Michel Carrier; Soon J Park
Journal:  Cardiol Res Pract       Date:  2011-02-08       Impact factor: 1.866

5.  Impella induced massive hemolysis: reemphasizing echocardiographic guidance for correct placement.

Authors:  Shaun Cardozo; Tasneem Ahmed; Kevin Belgrave
Journal:  Case Rep Cardiol       Date:  2015-01-27

6.  High-risk acute coronary syndrome in a patient with coronary subclavian steal syndrome secondary to critical subclavian artery stenosis.

Authors:  Zaher Fanari; Niksad Abraham; Sumaya Hammami; Wasif A Qureshi
Journal:  Case Rep Cardiol       Date:  2014-08-04
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.