Literature DB >> 15556359

Evaluation of a high-affinity QCM immunosensor using antibody fragmentation and 2-methacryloyloxyethyl phosphorylcholine (MPC) polymer.

Shigeru Kurosawa1, Miki Nakamura, Jong-Won Park, Hidenobu Aizawa, Kazunori Yamada, Mitsuo Hirata.   

Abstract

This study evaluated construction of a highly affinitive quartz crystal microbalance (QCM) immunosensor using anti-C-reactive protein (CRP) antibody and its fragments for CRP detection. Three types of antibody were immobilized on the surface of a QCM via covalent-bounding. Then affinity was evaluated through antigen-antibody binding between CRP and its antibody. Affinity between antigen-antibody was shown to be highest when anti-CRP F(ab')2-IgG antibody (70 microg/mL) was immobilized on the QCM. In case of anti-CRP F(ab')2-IgG antibody, affinity which was attributable to antigen-antibody binding was almost twice that of anti-CRP IgG antibody, which is used conventionally for QCM immunosensors. In addition, when it was treated with 2-methacryloyloxyethyl phosphorylcholine-co-n-butyl methacrylate, so-called MPC polymer, highly affinitive and selective immunosensing for CRP was achieved without non-specific binding from plasma proteins in human serum. When anti-CRP F(ab')2-IgG antibody was immobilized on the QCM, the detection limit and the linearity of CRP calibration curve were achieved at concentrations from 0.001 to 100 microg/dL even during investigation in serum samples. Experimental results verified the successful construction of a highly affinitive and selective QCM-immunosensor which was modified with anti-CRP F(ab')2-IgG antibody and MPC polymer.

Entities:  

Mesh:

Substances:

Year:  2004        PMID: 15556359     DOI: 10.1016/j.bios.2004.05.016

Source DB:  PubMed          Journal:  Biosens Bioelectron        ISSN: 0956-5663            Impact factor:   10.618


  5 in total

1.  Low-concentration mechanical biosensor based on a photonic crystal nanowire array.

Authors:  Yuerui Lu; Songming Peng; Dan Luo; Amit Lal
Journal:  Nat Commun       Date:  2011-12-06       Impact factor: 14.919

2.  A label-free immunosensor array using single-chain antibody fragments.

Authors:  Natalija Backmann; Christian Zahnd; Francois Huber; Alexander Bietsch; Andreas Plückthun; Hans-Peter Lang; Hans-Joachim Güntherodt; Martin Hegner; Christoph Gerber
Journal:  Proc Natl Acad Sci U S A       Date:  2005-09-28       Impact factor: 11.205

Review 3.  Comparative advantages of mechanical biosensors.

Authors:  J L Arlett; E B Myers; M L Roukes
Journal:  Nat Nanotechnol       Date:  2011-03-27       Impact factor: 39.213

4.  Recombinant antibody fragments allow repeated measurements of C-reactive protein with a quartz crystal microbalance immunosensor.

Authors:  Laila Al-Halabi; Anne Balck; Monika Michalzik; David Fröde; Stephanus Büttgenbach; Michael Hust; Thomas Schirrmann; Stefan Dübel
Journal:  MAbs       Date:  2012-12-06       Impact factor: 5.857

5.  Surface Modification of Silicon Nanowire Based Field Effect Transistors with Stimuli Responsive Polymer Brushes for Biosensing Applications.

Authors:  Stephanie Klinghammer; Sebastian Rauch; Sebastian Pregl; Petra Uhlmann; Larysa Baraban; Gianaurelio Cuniberti
Journal:  Micromachines (Basel)       Date:  2020-03-06       Impact factor: 2.891

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.