Literature DB >> 15556356

Design of an amperometric biosensor using polypyrrole-microgel composites containing glucose oxidase.

J Rubio Retama1, E López Cabarcos, D Mecerreyes, B López-Ruiz.   

Abstract

A new material consisting of a water-dispersed complex of polypyrrole-polystyrensulfonate (PPy) embedded in polyacrylamide (PA) has been prepared and tested as enzyme immobilizing system for its use in amperometric biosensors. Glucose oxidase (GOx) and the water-dispersed polypyrrole complex were entrapped within polyacrylamide microgels by polymerization of acrylamide in the dispersed phase of concentrated emulsions containing GOx and PPy. Polymerization of the dispersed phase provides microparticles whose size lies between 3.5 and 7 microm. The aim of incorporating polypyrrole into the polyacrylamide microparticles was to facilitate the direct transfer of the electrons released in the enzymatic reaction from the catalytic site to the platinum electrode surface. The conductivity of the microparticles was measured by a four-point probe method and confirmed by the successful anaerobic detection of glucose by the biosensor. Thus, the polyacrylamide-polypyrrole (PAPPy) microparticles combine the conductivity of polypyrrole and the pore size control of polyacrylamide. The effects of the polyacrylamide-polypyrrole ratio and cross-linking on the biosensor response have been investigated, as well as the influence of analytical parameters such as pH and enzymatic loading. The PAPPy biosensor is free of interferences arising from ascorbic and uric acids, which allows its use for quantitative analysis in human blood serum.

Entities:  

Mesh:

Substances:

Year:  2004        PMID: 15556356     DOI: 10.1016/j.bios.2004.05.018

Source DB:  PubMed          Journal:  Biosens Bioelectron        ISSN: 0956-5663            Impact factor:   10.618


  4 in total

1.  The effect of polypyrrole on arteriogenesis in an acute rat infarct model.

Authors:  Shirley S Mihardja; Richard E Sievers; Randall J Lee
Journal:  Biomaterials       Date:  2008-08-03       Impact factor: 12.479

2.  Direct Electron Transfer of Hemoglobin on Manganese III Oxide-Ag Nanofibers Modified Glassy Carbon Electrode.

Authors:  Masoud Negahdary; Gholamreza Mazaheri; Somyyeh Rad; Mohammadreza Hadi; Roya Malekzadeh; Mohammad Mahdi Saadatmand; Saeed Rezaei-Zarchi; Fariba Pishbin; Mojdeh Khosravian-Hemami
Journal:  Int J Anal Chem       Date:  2012-04-05       Impact factor: 1.885

Review 3.  Glucose biosensors: an overview of use in clinical practice.

Authors:  Eun-Hyung Yoo; Soo-Youn Lee
Journal:  Sensors (Basel)       Date:  2010-05-04       Impact factor: 3.576

4.  Sensing of Salivary Glucose Using Nano-Structured Biosensors.

Authors:  Yunqing Du; Wenjun Zhang; Ming L Wang
Journal:  Biosensors (Basel)       Date:  2016-03-17
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.