Multicentre performance evaluation of the E170 module for modular analytics.

Christian Bieglmayer1, Daniel W Chan, Lori Sokoll, Roland Imdahl, Masaji Kobayashi, Erike Yamada, Diana J Lilje, Hilmar Luthe, Jochen Meissner, Gianni Messeri, Alessandra Celli, Paola Tozzi, Heinz-Jürgen Roth, Frank-Peter Schmidt, Marie-Luise Mächler, Peter Schuff-Werner, Christiana Zingler, Johan Smitz, Johan Schiettecatte, Dieter J Vonderschmitt, Patrick Pei, Katherine Ng, Christoph Ebert, Peter Kirch, Michael Wanger, Margaret McGovern, Wolfgang Stockmann, Albert Kuns.   

Abstract

The E170 module was evaluated at 13 sites in an international multicentre study. The objective of the study was to assess the analytical performance of 49 analytes, and to collect feedback on the system's reliability and practicability. The typical, within-run coefficients of variation (CVs) for most of the quantitative assays ranged between 1 and 2% while a range of 2-4% was achieved with the infectious disease methods. Total precision CVs were found to be within the manufacturer's expected performance ranges, demonstrating good concordance of the system's measuring channels and a high reproducibility during the 2-4-week trial period. The functional sensitivity of 11 selected assays met the clinical requirements (e.g., thyreotroponin (TSH) 0.008 mU/l, troponin T 0.02 microg/l, total prostate-specific antigen (PSA) 0.03 microg/l). The E170 showed no drift during an 8-hour period and no relevant reagent carryover. Accuracy was confirmed by ring trial experiments and method comparisons vs. Elecsys 2010. The reliability and practicability of the system's hardware and software met with, or even exceeded, the evaluator's requirements. Workflow studies showed that E170 can cover the combined workload of various routine analysers in a variety of laboratory environment. Throughput and sample processing time requirements were achieved while personnel 'hands-on-time' could be reduced.

Entities:  

Mesh:

Substances:

Year:  2004        PMID: 15552279     DOI: 10.1515/CCLM.2004.239

Source DB:  PubMed          Journal:  Clin Chem Lab Med        ISSN: 1434-6621            Impact factor:   3.694


  5 in total

1.  Transgenic human C-reactive protein is not proatherogenic in apolipoprotein E-deficient mice.

Authors:  Gideon M Hirschfield; J Ruth Gallimore; Melvyn C Kahan; Winston L Hutchinson; Caroline A Sabin; G Martin Benson; Amar P Dhillon; Glenys A Tennent; Mark B Pepys
Journal:  Proc Natl Acad Sci U S A       Date:  2005-05-26       Impact factor: 11.205

2.  An innovative approach to functionality testing of analysers in the clinical laboratory.

Authors:  Wolfgang Stockmann; Werner Engeldinger; Albert Kunst; Margaret McGovern
Journal:  J Autom Methods Manag Chem       Date:  2008

3.  Increasing Efficiency and Quality by Consolidation of Clinical Chemistry and Immunochemistry Systems with MODULAR ANALYTICS SWA.

Authors:  Paolo Mocarelli; Gary L Horowitz; Pier Mario Gerthoux; Rossana Cecere; Roland Imdahl; Janneke Ruinemans-Koerts; Hilmar Luthe; Silvia Pesudo Calatayud; Marie Luisa Salve; Albert Kunst; Margaret McGovern; Katherine Ng; Wolfgang Stockmann
Journal:  J Autom Methods Manag Chem       Date:  2008

4.  Multicenter analytical evaluation of the automated electrochemiluminescence immunoassay for cyclosporine.

Authors:  Michael Vogeser; Maria Shipkova; Raül Rigo-Bonnin; Pierre Wallemacq; Matthias Orth; Monika Widmann; Alain G Verstraete
Journal:  Ther Drug Monit       Date:  2014-10       Impact factor: 3.681

5.  The Relationship of Functional Status of Cortisol, Testosterone, and Parameters of Metabolic Syndrome in Male Schizophrenics.

Authors:  Yi Han; Haifeng Ji; Li Liu; Yuncheng Zhu; Xixi Jiang
Journal:  Biomed Res Int       Date:  2020-10-22       Impact factor: 3.411

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.