Literature DB >> 15552151

Titanium and cobalt-chrome cementless femoral stems of identical shape produce equal results.

Young-Hoo Kim1.   

Abstract

This study of proximal porous-coated stems of identical shape, but with two types of stem materials (Ti alloy or Co-Cr alloy), was done to determine the differences, if any, in these stems in the following parameters: clinical and functional outcomes; the prevalence of thigh pain; the stem alignment and the stem-canal fill; cup position; the degree of periprosthetic bone loss; the prevalence of polyethylene liner wear and osteolysis; the incidence of aseptic loosening of acetabular and femoral components; and complication rates. In the Ti alloy group, there were 60 patients (70 hips) followed up for a mean of 6.4 years (range, 5-7 years) with a mean age at surgery of 45.3 years and a mean weight of 65.7 kg. In the Co-Cr alloy group, there were 60 patients (70 hips) followed up for a mean of 6.6 years (range, 5-7 years) with a mean age at surgery of 45.4 years and a mean weight of 66.8 kg. Harris hip scores did not differ and the prevalence of transient pain in the thigh was 5% with both stems. No acetabular or femoral component had aseptic loosening in either group. Loss of bone density in the calcar region was more severe in the Co-Cr group. The mean polyethylene linear wear per year was 0.15 mm (SD, 0.015) in the Ti group and 0.14 mm (SD, 0.013) in the Co-Cr group. No acetabular or femoral osteolysis was seen in any patient. The clinical and radiographic results of this study did not show any significant differences between the Ti and Co-Cr alloy femoral components; however, the Ti alloy femoral component retained greater periprosthetic bone as compared with a Co-Cr alloy femoral component.

Entities:  

Mesh:

Substances:

Year:  2004        PMID: 15552151     DOI: 10.1097/01.blo.0000142350.80416.84

Source DB:  PubMed          Journal:  Clin Orthop Relat Res        ISSN: 0009-921X            Impact factor:   4.176


  3 in total

1.  Finite element analysis of cementless femoral stems based on mid- and long-term radiological evaluation.

Authors:  Kanehiro Matsuyama; Yasuhiro Ishidou; Yong-Ming Guo; Hironori Kakoi; Takao Setoguchi; Satoshi Nagano; Ichiro Kawamura; Shingo Maeda; Setsuro Komiya
Journal:  BMC Musculoskelet Disord       Date:  2016-09-19       Impact factor: 2.362

2.  Fracture of cobalt chrome, fully-coat beaded femoral revision long stem, a clinical outcomes study.

Authors:  Chih-Hsiang Chang; Po-Chun Lin; Cheng-Min Shih; Chun-Chieh Chen; Pang-Hsin Hsieh; Hsin-Nung Shih
Journal:  Biomed J       Date:  2018-03-30       Impact factor: 4.910

Review 3.  Ultra-Short Bone Conserving Cementless Femoral Stem.

Authors:  Young-Hoo Kim
Journal:  Hip Pelvis       Date:  2021-12-01
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.