Literature DB >> 15552115

Magnetic resonance imaging of radiation dose distributions using a polymer-gel dosimeter.

M J Maryanski1, R J Schulz, G S Ibbott, J C Gatenby, J Xie, D Horton, J C Gore.   

Abstract

A new formulation of a tissue-equivalent polymer-gel dosimeter for the measurement of three-dimensional dose distributions of ionizing radiation has been developed. It is composed of aqueous gelatin infused with acrylamide and N, N'-methylene-bisacrylamide monomers, and made hypoxic by nitrogen saturation. Irradiation of the gel, referred to as BANG, causes localized polymerization of the monomers, which, in turn, reduces the transverse NMR relaxation times of water protons. The dose dependence of the NMR transverse relaxation rate, R2, is reproducible (less than 2% variation) and is linear up to about 8 Gy, with a slope of 0.25 s(-1)Gy(-1) at 1.5 T. Magnetic resonance imaging may be used to obtain accurate three-dimensional dose distributions with high spatial resolution. Since the radiation-induced polymers do not diffuse through the gelatin matrix, the dose distributions recorded by BANG gels are stable for long periods of time, and may be used to measure low-activity radioactive sources. Since the light-scattering properties of the polymerized regions are different from those of the clear, non-irradiated regions, the dose distributions are visible, and their optical densities are dependent on dose.

Entities:  

Mesh:

Substances:

Year:  1994        PMID: 15552115     DOI: 10.1088/0031-9155/39/9/010

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  26 in total

1.  A quantitative study of magnetization transfer in MAGIC gels.

Authors:  Daniel F Gochberg; Peter M Fong; John C Gore
Journal:  Phys Med Biol       Date:  2003-11-07       Impact factor: 3.609

2.  A practical three-dimensional dosimetry system for radiation therapy.

Authors:  Pengyi Guo; John Adamovics; Mark Oldham
Journal:  Med Phys       Date:  2006-10       Impact factor: 4.071

3.  Fast, high-resolution 3D dosimetry utilizing a novel optical-CT scanner incorporating tertiary telecentric collimation.

Authors:  H S Sakhalkar; M Oldham
Journal:  Med Phys       Date:  2008-01       Impact factor: 4.071

4.  3D dosimetry by optical-CT scanning.

Authors:  Mark Oldham
Journal:  J Phys Conf Ser       Date:  2006

5.  Influencing Factors on Reproducibility and Stability of MRI NIPAM Polymer Gel Dosimeter.

Authors:  Farideh Pak; Alireza Farajollahi; Ali Movafaghi; Alireza Naseri
Journal:  Bioimpacts       Date:  2013-07-14

6.  A variable echo-number method for estimating R2 in MRI-based polymer gel dosimetry.

Authors:  Yoichi Watanabe; Hitoshi Kubo
Journal:  Med Phys       Date:  2011-02       Impact factor: 4.071

7.  On the feasibility of polyurethane based 3D dosimeters with optical CT for dosimetric verification of low energy photon brachytherapy seeds.

Authors:  Justus Adamson; Yun Yang; Titania Juang; Kelsey Chisholm; Leith Rankine; John Adamovics; Fang Fang Yin; Mark Oldham
Journal:  Med Phys       Date:  2014-07       Impact factor: 4.071

8.  Optical cone beam tomography of Cherenkov-mediated signals for fast 3D dosimetry of x-ray photon beams in water.

Authors:  Adam K Glaser; Jacqueline M Andreozzi; Rongxiao Zhang; Brian W Pogue; David J Gladstone
Journal:  Med Phys       Date:  2015-07       Impact factor: 4.071

9.  Projection imaging of photon beams by the Čerenkov effect.

Authors:  Adam K Glaser; Scott C Davis; David M McClatchy; Rongxiao Zhang; Brian W Pogue; David J Gladstone
Journal:  Med Phys       Date:  2013-01       Impact factor: 4.071

10.  Commissioning a CT-compatible LDR tandem and ovoid applicator using Monte Carlo calculation and 3D dosimetry.

Authors:  Justus Adamson; Joseph Newton; Yun Yang; Beverly Steffey; Jing Cai; John Adamovics; Mark Oldham; Junzo Chino; Oana Craciunescu
Journal:  Med Phys       Date:  2012-07       Impact factor: 4.071

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.