Literature DB >> 15552079

Dose-response curve slope improvement and result reproducibility of ferrous-sulphate-doped gels analysed by NMR imaging.

G Gambarini1, S Arrigoni, M C Cantone, N Molho, L Facchielli, A E Sichirollo.   

Abstract

Ferrous sulphate gel analysed by relaxation time measurements with NMR imaging is considered a useful dosimeter for 3D determinations of absorbed dose. A protocol for the gel preparation with agarose SeaPlaque that leads to a dosimeter with very high dose sensitivity is described. The dose-response curve slope is about 0.2 s(-1) Gy(-1) and the G factor turns out to be approximately 185 ions per 100 eV of absorbed energy. A method for making the measurements and analysing the results that brings about good result reproducibility is suggested. A thorough experimental study of the dependence of the dosimeter response on the elapsed time from preparation to irradiation and from irradiation to NMR measurement has revealed good reproducibility. The above characteristic of the gel system is very interesting, because it shows the possibility of utilizing the dosimeter for absolute dose determinations with satisfactory reliability.

Entities:  

Mesh:

Substances:

Year:  1994        PMID: 15552079     DOI: 10.1088/0031-9155/39/4/004

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  4 in total

1.  Study of the Optimal Composition and Storage Conditions of the Fricke-XO-Pluronic F-127 Radiochromic Dosimeter.

Authors:  Michał Piotrowski; Piotr Maras; Sławomir Kadłubowski; Marek Kozicki
Journal:  Materials (Basel)       Date:  2022-01-27       Impact factor: 3.623

Review 2.  Radiation Dosimetry by Use of Radiosensitive Hydrogels and Polymers: Mechanisms, State-of-the-Art and Perspective from 3D to 4D.

Authors:  Yves De Deene
Journal:  Gels       Date:  2022-09-19

3.  Prevention of transfusion-associated graft-versus-host disease by irradiation: technical aspect of a new ferrous sulphate dosimetric system.

Authors:  Lucas Sacchini Del Lama; Evamberto Garcia de Góes; Paulo César Dias Petchevist; Edson Lara Moretto; José Carlos Borges; Dimas Tadeu Covas; Adelaide de Almeida
Journal:  PLoS One       Date:  2013-06-07       Impact factor: 3.240

4.  Fricke gel dosimeter with improved sensitivity for low-dose-level measurements.

Authors:  Mauro Valente; Wladimir Molina; Lila Carrizales Silva; Rodolfo Figueroa; Francisco Malano; Pedro Pérez; Mauricio Santibañez; José Vedelago
Journal:  J Appl Clin Med Phys       Date:  2016-07-08       Impact factor: 2.102

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.