Literature DB >> 15551539

Accelerated EM reconstruction in total-body PET: potential for improving tumour detectability.

S R Meikle1, B F Hutton, D L Bailey, P K Hooper, M J Fulham.   

Abstract

Total-body positron emission tomography (PET) is a useful diagnostic tool for evaluating malignant disease. However, tumour detection is limited by image artefacts due to the lack of attenuation correction and noise. Attenuation correction may be possible using transmission data acquired after or simultaneously with emission data. Despite the elimination of attenuation artefacts, however, tumour detection is still hampered by noise, which is amplified during image reconstruction by filtered backprojection (FBP). We have investigated, as an alternative to FBP, an accelerated expectation maximization (EM) algorithm for its potential to improve tumour detectability in total-body PET. Signal to noise ratio (SNR), calculated for a tumour with respect to the surrounding background, is used as a figure of merit. A software tumour phantom, with conditions typical of those encountered in a total-body PET study using simultaneous acquisition, is used to optimize and compare various reconstruction approaches. Accelerated EM reconstruction followed by two-dimensional filtering is shown to yield significantly higher SNR than FBP for a range of tumour sizes, concentrations and counting statistics (deltaSNR = 6.3 +/- 3.9, p < 0.001). The methods developed are illustrated by examples derived from physical phantom and patient data.

Entities:  

Mesh:

Year:  1994        PMID: 15551539     DOI: 10.1088/0031-9155/39/10/012

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  3 in total

1.  Image reconstruction for PET/CT scanners: past achievements and future challenges.

Authors:  Shan Tong; Adam M Alessio; Paul E Kinahan
Journal:  Imaging Med       Date:  2010-10-01

2.  An evaluation of iterative reconstruction strategies based on mediastinal lesion detection using hybrid Ga-67 SPECT images.

Authors:  Nicholas F Pereira; Howard C Gifford; P Hendrik Pretorius; Mark Smyczynski; Robert Licho; Peter Schneider; Troy Farncombe; Michael A King
Journal:  Med Phys       Date:  2008-11       Impact factor: 4.071

3.  Optimisation of the OS-EM algorithm and comparison with FBP for image reconstruction on a dual-head camera: a phantom and a clinical 18F-FDG study.

Authors:  Fabrice Gutman; Isabelle Gardin; Nicolas Delahaye; Hervé Rakotonirina; Anne Hitzel; Alain Manrique; Dominique Le Guludec; Pierre Véra
Journal:  Eur J Nucl Med Mol Imaging       Date:  2003-09-23       Impact factor: 9.236

  3 in total