Literature DB >> 15548808

Visual acuity and the ability of the visually impaired to read medication instructions.

S R Drummond1, R S Drummond, G N Dutton.   

Abstract

BACKGROUND/AIMS: Although medical information is often communicated in writing, little attention is given as to whether patients can read it--for example, the miniscule writing on the side of the medication bottles (equivalent to 6/6 reduced Snellen). The authors wished to determine a distance visual acuity threshold, using routine assessments of visual acuity (VA), beyond which patients are unable to read their instructions.
METHODS: 180 patients, subgrouped according to the best line of Snellen acuity (from 6/9 to 6/60) achieved in either eye were recruited. Subjects were asked to read the printed manufacturer's instructions on the side of the drops box without magnification.
RESULTS: Those subjects with best corrected VA of lower than or equal to 6/24 showed a significantly diminished ability to read the instructions on their eye drops bottles (p<0.001 for each comparison). When this group selected a font size of their choosing, the mode for preferred Arial font sizes were 16 for the 6/24 group, 18 for 6/36, and 22 for 6/60.
CONCLUSION: This study documents the inability of patients with visual impairment to read the instructions on their bottle of eye drops. There is evidence of a distance VA threshold effect such that, although the majority of patients with 6/18 VA are able to read their instructions, patients whose VA is worse cannot. This latter group would benefit from a larger font size, a size of Arial 22 being sufficient. We recommend that all printed information for patients with visual acuities between 6/24 and 6/60 be printed in font Arial 22 or equivalent.

Entities:  

Mesh:

Substances:

Year:  2004        PMID: 15548808      PMCID: PMC1772422          DOI: 10.1136/bjo.2003.029918

Source DB:  PubMed          Journal:  Br J Ophthalmol        ISSN: 0007-1161            Impact factor:   4.638


  2 in total

1.  Writing to our patients.

Authors:  G J Menon; G N Dutton
Journal:  Br J Ophthalmol       Date:  1999-07       Impact factor: 4.638

2.  Listening and talking to patients. III: The exposition.

Authors:  C Fletcher
Journal:  Br Med J       Date:  1980-10-11
  2 in total
  3 in total

1.  Reading Ability among Patients Presenting for Ophthalmic and Nonophthalmic Surgery.

Authors:  Regina A de Luna; Angeline M Nguyen; Pradeep Y Ramulu
Journal:  Ophthalmology       Date:  2017-01-26       Impact factor: 12.079

2.  Design and test of preference for a new prescription medication label.

Authors:  Amir H Zargarzadeh; Anandi V Law
Journal:  Int J Clin Pharm       Date:  2011-03-12

Review 3.  Aging: a predisposition to dry eyes.

Authors:  Anushree Sharma; Holly B Hindman
Journal:  J Ophthalmol       Date:  2014-08-14       Impact factor: 1.909

  3 in total