Improved precision and accuracy for high-performance liquid chromatography/Fourier transform ion cyclotron resonance mass spectrometric exact mass measurement of small molecules from the simultaneous and controlled introduction of internal calibrants via a second electrospray nebuliser.

Julie M Herniman1, Tony W T Bristow, Gavin O'Connor, Jackie Jarvis, G John Langley.   

Abstract

The use of a second electrospray nebuliser has proved to be highly successful for exact mass measurement during high-performance liquid chromatography/Fourier transform ion cyclotron resonance mass spectrometry (HPLC/FTICRMS). Much improved accuracy and precision of mass measurement were afforded by the introduction of the internal calibration solution, thus overcoming space charge issues due to the lack of control over relative ion abundances of the species eluting from the HPLC column. Further, issues of suppression of ionisation, observed when using a T-piece method, are addressed and this simple system has significant benefits over other more elaborate approaches providing data that compares very favourably with these other approaches. The technique is robust, flexible and transferable and can be used in conjunction with HPLC, infusion or flow injection analysis (FIA) to provide constant internal calibration signals to allow routine, accurate and precise mass measurements to be recorded. Copyright 2004 John Wiley & Sons, Ltd.

Mesh:

Substances:

Year:  2004        PMID: 15543531     DOI: 10.1002/rcm.1729

Source DB:  PubMed          Journal:  Rapid Commun Mass Spectrom        ISSN: 0951-4198            Impact factor:   2.419


  4 in total

1.  Steady-state asymmetric nanospray dual ion source for accurate mass determination within a chromatographic separation.

Authors:  Nicolas L Young; Michael C Sisto; Meggie N Young; Patrick G Grant; David W Killilea; LaTasha LaMotte; Kuang Jen J Wu; Carlito B Lebrilla
Journal:  Anal Chem       Date:  2007-07-06       Impact factor: 6.986

2.  Elimination of systematic mass measurement errors in liquid chromatography-mass spectrometry based proteomics using regression models and a priori partial knowledge of the sample content.

Authors:  Vladislav A Petyuk; Navdeep Jaitly; Ronald J Moore; Jie Ding; Thomas O Metz; Keqi Tang; Matthew E Monroe; Aleksey V Tolmachev; Joshua N Adkins; Mikhail E Belov; Alan R Dabney; Wei-Jun Qian; David G Camp; Richard D Smith
Journal:  Anal Chem       Date:  2007-12-29       Impact factor: 6.986

3.  DtaRefinery, a software tool for elimination of systematic errors from parent ion mass measurements in tandem mass spectra data sets.

Authors:  Vladislav A Petyuk; Anoop M Mayampurath; Matthew E Monroe; Ashoka D Polpitiya; Samuel O Purvine; Gordon A Anderson; David G Camp; Richard D Smith
Journal:  Mol Cell Proteomics       Date:  2009-12-17       Impact factor: 5.911

4.  Mass recalibration of FT-ICR mass spectrometry imaging data using the average frequency shift of ambient ions.

Authors:  Jeremy A Barry; Guillaume Robichaud; David C Muddiman
Journal:  J Am Soc Mass Spectrom       Date:  2013-05-29       Impact factor: 3.109

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.