Literature DB >> 1554289

Inaccuracy of cardiac output by thermodilution during acute tricuspid regurgitation.

P M Heerdt1, C G Pond, G A Blessios, M Rosenbloom.   

Abstract

We have been comparing cardiac output measured with a novel Doppler pulmonary artery catheter to that measured by thermodilution and aortic electromagnetometry in cardiac surgical patients. We report here our observation of a nearly twofold increase in thermodilution cardiac output after the acute intraoperative onset of tricuspid regurgitation that was not confirmed by the novel catheter or direct measurement of aortic blood flow. We conclude that in some patients, acute tricuspid regurgitation may lessen the reliability of thermodilution cardiac output.

Entities:  

Mesh:

Year:  1992        PMID: 1554289     DOI: 10.1016/0003-4975(92)90342-2

Source DB:  PubMed          Journal:  Ann Thorac Surg        ISSN: 0003-4975            Impact factor:   4.330


  10 in total

Review 1.  [Measurement of cardiac output].

Authors:  D A Reuter; A E Goetz
Journal:  Anaesthesist       Date:  2005-11       Impact factor: 1.041

2.  Right heart catheterisation may be cautiously performed through a mechanical valve prosthesis in the tricuspid position.

Authors:  Stephen Pettit; Steven Tsui; Jayan Parameshwar
Journal:  BMJ Case Rep       Date:  2016-04-13

3.  Impact of Catheterization Lab Computer Software Settings on Hemodynamic Assessment of Aortic Stenosis.

Authors:  Zaher Fanari; Anitha Rajamanickam; Mathew Grove; Sumaya Hammami; Cassie Walls; Paul Kolm; William Weintraub; Andrew J Doorey
Journal:  Del Med J       Date:  2016-07

4.  The Impact of Direct Cardiac Output Determination On Using A Widely Available Direct Continuous Oxygen Consumption Measuring Device On The Hemodynamic Assessment of Aortic Valve.

Authors:  Zaher Fanari; Matthew Grove; Anitha Rajamanickam; Sumaya Hammami; Cassie Walls; Paul Kolm; Mitchell Saltzberg; William S Weintraub; Andrew J Doorey
Journal:  Del Med J       Date:  2016-09

5.  Cardiac output determination using a widely available direct continuous oxygen consumption measuring device: a practical way to get back to the gold standard.

Authors:  Zaher Fanari; Matthew Grove; Anitha Rajamanickam; Sumaya Hammami; Cassie Walls; Paul Kolm; Mitchell Saltzberg; William S Weintraub; Andrew J Doorey
Journal:  Cardiovasc Revasc Med       Date:  2016-02-27

6.  Differences of cardiac output measurements by open-circuit acetylene uptake in pulmonary arterial hypertension and chronic thromboembolic pulmonary hypertension: a cohort study.

Authors:  Martin Schwaiblmair; Christian Faul; Wolfgang von Scheidt; Thomas M Berghaus
Journal:  Respir Res       Date:  2012-03-12

7.  ICU management based on PiCCO parameters reduces duration of mechanical ventilation and ICU length of stay in patients with severe thoracic trauma and acute respiratory distress syndrome.

Authors:  Zhong Yuanbo; Wang Jin; Shi Fei; Long Liangong; Liu Xunfa; Xu Shihai; Shan Aijun
Journal:  Ann Intensive Care       Date:  2016-11-21       Impact factor: 6.925

8.  Cardioprotective shock management: monitoring and supportive therapies.

Authors:  David Schibilsky; Clement Delmas; Laurent Bonello; Patrick Hunziker
Journal:  Eur Heart J Suppl       Date:  2021-03-27       Impact factor: 1.803

9.  Use of the PiCCO system in critically ill patients with septic shock and acute respiratory distress syndrome: a study protocol for a randomized controlled trial.

Authors:  Zhongheng Zhang; Xiao Xu; Min Yao; Huilan Chen; Hongying Ni; Haozhe Fan
Journal:  Trials       Date:  2013-02-01       Impact factor: 2.279

10.  Cardiac output measured by transthoracic echocardiography and Swan-Ganz catheter. A comparative study in mechanically ventilated patients with high positive end-expiratory pressure.

Authors:  José Gorrasi; Arturo Pazos; Lucia Florio; Carlos Américo; Natalia Lluberas; Gabriel Parma; Ricardo Lluberas
Journal:  Rev Bras Ter Intensiva       Date:  2019 Oct-Dec
  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.