Literature DB >> 15541280

Enzyme-linked immunomagnetic chemiluminescent detection of Escherichia coli O157:H7.

Andrew G Gehring1, Peter L Irwin, Sue A Reed, Shu-I Tu, Peter E Andreotti, Hashem Akhavan-Tafti, Richard S Handley.   

Abstract

E. coli O157:H7 is a pathogenic microorganism that has been implicated in numerous cases of foodborne illnesses. A variety of rapid methods exist that show promise for the presumptive detection of this pathogen without the immediate need for incubating test samples for hours to days in microbial enrichment and culture media. In recent years, highly sensitive chemiluminescence has become a more affordable and portable detection method. Chemiluminescent detection has been coupled with the selectivity of antibodies, magnetic microparticle separation/isolation, and enzymatic signal amplification in order to develop a rapid method, termed enzyme-linked immunomagnetic chemiluminescence (ELIMCL). This work presents the application of ELIMCL to the detection of E. coli O157:H7 in pristine buffered saline with a detection limit of 7.6 x 10(3) for live cells in approx. 75 min assay time. The blocking agent casein and the surfactant Tween 20 were used to lower background luminescence and thus maximize signal-to-noise ratios. After 5.5 h of enrichment culture, ELIMCL was demonstrated to detect E. coli O157:H7 inoculated in ground beef at 10 CFU/g in a total assay time of about 7 h.

Entities:  

Mesh:

Year:  2004        PMID: 15541280     DOI: 10.1016/j.jim.2004.07.004

Source DB:  PubMed          Journal:  J Immunol Methods        ISSN: 0022-1759            Impact factor:   2.303


  7 in total

1.  Rapid affinity immunochromatography column-based tests for sensitive detection of Clostridium botulinum neurotoxins and Escherichia coli O157.

Authors:  Jason Brunt; Martin D Webb; Michael W Peck
Journal:  Appl Environ Microbiol       Date:  2010-04-30       Impact factor: 4.792

2.  Flow-orthogonal bead oscillation in a microfluidic chip with a magnetic anisotropic flux-guide array.

Authors:  Stijn van Pelt; Roy Derks; Marco Matteucci; Mikkel Fougt Hansen; Andreas Dietzel
Journal:  Biomed Microdevices       Date:  2011-04       Impact factor: 2.838

3.  Modeling and predicting the simultaneous growth of Escherichia coli O157:H7 and ground beef background microflora for various enrichment protocols.

Authors:  A Vimont; C Vernozy-Rozand; M P Montet; C Lazizzera; C Bavai; M-L Delignette-Muller
Journal:  Appl Environ Microbiol       Date:  2006-01       Impact factor: 4.792

4.  Capture of Escherichia coli O157:H7 Using Immunomagnetic Beads of Different Size and Antibody Conjugating Chemistry.

Authors:  Shu-I Tu; Sue Reed; Andrew Gehring; Yiping He; George Paoli
Journal:  Sensors (Basel)       Date:  2009-01-29       Impact factor: 3.576

5.  An Electrochemical Strategy using Multifunctional Nanoconjugates for Efficient Simultaneous Detection of Escherichia coli O157: H7 and Vibrio cholerae O1.

Authors:  Yan Li; Ya Xiong; Lichao Fang; Lili Jiang; Hui Huang; Jun Deng; Wenbin Liang; Junsong Zheng
Journal:  Theranostics       Date:  2017-02-21       Impact factor: 11.556

6.  Fast immunosensing technique to detect Legionella pneumophila in different natural and anthropogenic environments: comparative and collaborative trials.

Authors:  Begoña Bedrina; Sonia Macián; Inmaculada Solís; Roberto Fernández-Lafuente; Eva Baldrich; Guillermo Rodríguez
Journal:  BMC Microbiol       Date:  2013-04-22       Impact factor: 3.605

7.  Recent advances in molecular technologies and their application in pathogen detection in foods with particular reference to yersinia.

Authors:  Jin Gui; Isha R Patel
Journal:  J Pathog       Date:  2011-10-29
  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.