Evaluation of renovascular hypertension: comparison of functional MRI and contrast-enhanced MRA with a routinely performed renal scintigraphy and DSA.

Thomas Hackländer1, Heinrich Mertens, Jörg Stattaus, Michaela Lürken, Hartmut Lerch, Alexander Altenburg, Jeannette Rautenbach, Bernhard M Cramer.   

Abstract

OBJECTIVE: The main objective of this study was to evaluate a clinically suspected renovascular hypertension (RVH) by means of MRI. It was to find out if functional MRI (fMRI) is able to provide adequate results with regard to MAG3 captopril scintigraphy and if contrast-enhanced MR angiography (MRA) is able to provide adequate results in the stenosis grading compared with the nonselective digital subtraction angiography (DSA).
METHODS: This open, monocentric, prospective, phase 3 study included patients with a clinically suspected RVH. For fMRI a dynamic TurboFLASH sequence and for MRA a single-shot breath-hold flash 3D sequence was performed. Gadodiamide was injected as contrast medium.
RESULTS: Sixty patients were included in the study. The correlation between fMRI and scintigraphy had an accuracy, a sensitivity, and a specificity of 69%, 5%, and 92%, respectively, and correlations between MRA and DSA of 95%, 92%, and 96%.
CONCLUSION: The noninvasive MRA can replace DSA in the diagnosis of renal artery stenosis. However, fMRI can not replace renal scintigraphy.

Entities:  

Mesh:

Substances:

Year:  2004        PMID: 15538158     DOI: 10.1097/00004728-200411000-00016

Source DB:  PubMed          Journal:  J Comput Assist Tomogr        ISSN: 0363-8715            Impact factor:   1.826


  3 in total

1.  Non-invasive imaging cannot replace formal angiography in the diagnosis of renovascular hypertension.

Authors:  Agnes Trautmann; Derek J Roebuck; Clare A McLaren; Eileen Brennan; Stephen D Marks; Kjell Tullus
Journal:  Pediatr Nephrol       Date:  2016-10-17       Impact factor: 3.714

2.  Renal Doppler evaluation in the child with hypertension: a reasonable screening discriminator?

Authors:  Sumit Chhadia; Richard A Cohn; Gulsah Vural; James S Donaldson
Journal:  Pediatr Radiol       Date:  2013-07-17

Review 3.  Imaging in the evaluation of renovascular disease.

Authors:  Kjell Tullus; Derek J Roebuck; Clare A McLaren; Stephen D Marks
Journal:  Pediatr Nephrol       Date:  2009-10-24       Impact factor: 3.714

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.