Literature DB >> 15534821

MCG to ECG source differences: measurements and a two-dimensional computer model study.

Rodrigo Weber Dos Santos1, Olaf Kosch, Uwe Steinhoff, Steffen Bauer, Lutz Trahms, Hans Koch.   

Abstract

In this work we combine body surface potential map (BSPM) and magnetocardiogram (MCG) measurements with computer simulations in order to elucidate a recent thesis that claims the orthogonality of the main sources of MCG and ECG. Body surface currents and MCG pseudo currents are calculated from measured BSPM and MCG data, respectively. In contrast to the MCG-ECG source orthogonality thesis, we observe the main orientation of the BSPM currents and MCG pseudo currents to have similar axis during most of the depolarization R wave. In an attempt to explain such measurements we simulate a 2D transmural slice of the left ventricle in contact to a volume conductor. The main magnetic source currents along the wave front are indeed orthogonal to the extracellular electric current. However, fiber orientation inhomogeneity through the ventricular wall, volume conductor interface, wave front shape and extra- and intracellular potential distributions, all distort the symmetry of the current loops that contain the wave front currents. The resulting asymmetry rotates the main axis of the pseudo MCG currents away from the orthogonal axis of the body surface currents. Thus, the simulation results could solve the apparent contradiction between the orthogonal source theory and the observed similar ECG and MCG main current axis.

Entities:  

Mesh:

Year:  2004        PMID: 15534821     DOI: 10.1016/j.jelectrocard.2004.08.036

Source DB:  PubMed          Journal:  J Electrocardiol        ISSN: 0022-0736            Impact factor:   1.438


  3 in total

1.  Measurements of transmembrane potential and magnetic field at the apex of the heart.

Authors:  Krista Kay McBride; Bradley J Roth; V Y Sidorov; John P Wikswo; Franz J Baudenbacher
Journal:  Biophys J       Date:  2010-11-17       Impact factor: 4.033

2.  Surface current density mapping for identification of gastric slow wave propagation.

Authors:  L Alan Bradshaw; Leo K Cheng; William O Richards; Andrew J Pullan
Journal:  IEEE Trans Biomed Eng       Date:  2009-04-28       Impact factor: 4.538

3.  Pseudo current density maps of electrophysiological heart, nerve or brain function and their physical basis.

Authors:  Wolfgang Haberkorn; Uwe Steinhoff; Martin Burghoff; Olaf Kosch; Andreas Morguet; Hans Koch
Journal:  Biomagn Res Technol       Date:  2006-10-13
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.