Contact mechanics analysis of metal-on-metal hip resurfacing prostheses.

I J Udofia1, A Yew, Z M Jin.   

Abstract

Finite-element method was employed to study the contact mechanics in metal-on-metal hip resurfacing prostheses, with particular reference to the effects of bone quality, the fixation condition between the acetabular cup and bone, and the clearance between the femoral head and the acetabular cup. Simple finite-element bone models were developed to simulate the contact between the articulating surfaces of the femoral head and the acetabular cup. The stresses within the bone structure were also studied. It was shown that a decrease in the clearance between the acetabular cup and femoral head had the largest effect on reducing the predicted contact-pressure distribution among all the factors considered in this study. It was found that as the clearance was reduced, the influence of the underlying materials, such as bone and cement, became increasingly important. Stress shielding was determined to occur in the bone tissue surrounding the hip resurfacing prosthesis considered in this study. However, the stress-shielding effects predicted were less than those observed in conventional total hip replacements. Both the effects of bone quality (reduction in elastic modulus) and the fixation condition between the cup and the bone were found to have a negligible effect on the predicted contact mechanics at the bearing surface. The loading was found to have a relatively small effect on the predicted maximum contact pressure at the bearing surface; this was attributed to an increase in contact area as the load was increased.

Entities:  

Mesh:

Substances:

Year:  2004        PMID: 15532995     DOI: 10.1243/0954411041932854

Source DB:  PubMed          Journal:  Proc Inst Mech Eng H        ISSN: 0954-4119            Impact factor:   1.617


  5 in total

1.  Physical validation of a patient-specific contact finite element model of the ankle.

Authors:  Donald D Anderson; Jane K Goldsworthy; Wendy Li; M James Rudert; Yuki Tochigi; Thomas D Brown
Journal:  J Biomech       Date:  2007-04-12       Impact factor: 2.712

2.  Edge-loading severity as a function of cup lip radius in metal-on-metal total hips--a finite element analysis.

Authors:  Jacob M Elkins; Karen M Kruger; Douglas R Pedersen; John J Callaghan; Thomas D Brown
Journal:  J Orthop Res       Date:  2011-08-02       Impact factor: 3.494

Review 3.  Systemic and local toxicity of metal debris released from hip prostheses: A review of experimental approaches.

Authors:  Divya Rani Bijukumar; Abhijith Segu; Júlio C M Souza; XueJun Li; Mark Barba; Louis G Mercuri; Joshua J Jacobs; Mathew Thoppil Mathew
Journal:  Nanomedicine       Date:  2018-01-12       Impact factor: 5.307

4.  Bone mineral density of the proximal femur after hip resurfacing arthroplasty: 1-year follow-up study.

Authors:  Arja Häkkinen; Håkan Borg; Mikko Hakulinen; Jukka Jurvelin; Esa Anttila; Tapani Parviainen; Ilkka Kiviranta
Journal:  BMC Musculoskelet Disord       Date:  2011-05-19       Impact factor: 2.362

5.  Multi-body simulation of a canine hind limb: model development, experimental validation and calculation of ground reaction forces.

Authors:  Gabriele Helms; Bernd-Arno Behrens; Martin Stolorz; Patrick Wefstaedt; Ingo Nolte
Journal:  Biomed Eng Online       Date:  2009-11-23       Impact factor: 2.819

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.