Literature DB >> 15529955

Identification of milling parameters for manual cutting of bicortical bone structures.

P Bast1, M Engelhardt, W Lauer, K Schmieder, V Rohde, K Radermacher.   

Abstract

Within the framework of the development of a new neurosurgical robot system, parameters of conventional manual neurosurgical bone milling had to be determined. These results were used as a reference for the design and validation of the robotic versus manual milling task. Bovine scapulae were used for the tests because their bicortical structure is similar to the bone structure of the skull. The exercise was to cut defined geometries that had been registered on the bone prior to the start of the milling operation. The geometries had to be milled with a depth of 3 mm, which corresponded to the radius of the ball of the cutter. Different parameters like tool position, rotary speed, temperature, forces and time were registered. Eleven experienced neurosurgeons with practical experience of 80-1200 skull operations participated in this study. First results show a large variation in depth along the line. The lateral deviation was up to 5 mm, the depth error up to 2.5 mm, the tool temperature was 22 degrees C to 65 degrees C, and rotary speed varied from 15,000 to 80,000 rpm. Registered forces had maxima of 16 N in the feed direction and 21 N normal to the surface; average forces were approximately 1-2 N.

Entities:  

Mesh:

Year:  2003        PMID: 15529955     DOI: 10.3109/10929080309146061

Source DB:  PubMed          Journal:  Comput Aided Surg        ISSN: 1092-9088


  4 in total

1.  Fast and accurate registration of cranial CT images with A-mode ultrasound.

Authors:  Lorenz Fieten; Kirsten Schmieder; Martin Engelhardt; Lamija Pasalic; Klaus Radermacher; Stefan Heger
Journal:  Int J Comput Assist Radiol Surg       Date:  2009-03-13       Impact factor: 2.924

2.  Use of autologous scapula for cranioplasty: cadaveric feasibility study.

Authors:  R Shane Tubbs; Marios Loukas; Mohammadali M Shoja; Frank Salter; E George Salter; W Jerry Oakes
Journal:  Childs Nerv Syst       Date:  2008-02-26       Impact factor: 1.475

3.  An experimental evaluation of the force requirements for robotic mastoidectomy.

Authors:  Neal P Dillon; Louis B Kratchman; Mary S Dietrich; Robert F Labadie; Robert J Webster; Thomas J Withrow
Journal:  Otol Neurotol       Date:  2013-09       Impact factor: 2.311

4.  MINARO HD: control and evaluation of a handheld, highly dynamic surgical robot.

Authors:  Manuel Vossel; Meiko Müller; Annegret Niesche; Lukas Theisgen; Klaus Radermacher; Matías de la Fuente
Journal:  Int J Comput Assist Radiol Surg       Date:  2021-01-23       Impact factor: 2.924

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.