Literature DB >> 15529839

Diagnosis of palpable breast masses: ultrasound-guided large core biopsy in a multidisciplinary setting.

Hernan I Vargas1, M Perla Vargas, Katherine D Gonzalez, Rose Venegas, Martha Canet, Melissa Burla, Kamal Eldrageely, Iraj Khalkhali.   

Abstract

Cytologic diagnosis of palpable breast masses is an accepted method for diagnosis. However, the high nondiagnostic rate causes repeat biopsy, unnecessary delays, and increased costs. Our purpose is to evaluate the use of ultrasound (US)-guided large-core needle biopsy as part of the minimally invasive multidisciplinary diagnosis of palpable breast masses. We studied 502 consecutive patients with 510 palpable solid breast masses seen and evaluated by a multidisciplinary team. Patients had US-guided core biopsy. Clinical-imaging-pathologic correlation (CIPC) was done in all cases. Core biopsy was deemed conclusive if CIPC was congruent and was used to guide definitive management. The median age of our patients was 39 years. Median tumor size was 2.2 cm. Of these cases, 463 (91%) had a conclusive diagnosis on CIPC. Core needle findings on 47 masses were nondefinitive to guide therapy (fibroepithelial lesion, atypical ductal hyperplasia, intraductal papilloma, CIPC). Three cancers were detected in this group on excisional biopsy. In conclusion, US-guided large-core needle biopsy is a sensitive method for diagnosis of palpable breast masses. Multidisciplinary correlation of clinical findings, imaging, and pathology is essential for success. This approach improves use of operating room resources and maximizes patient participation in the decision-making process.

Entities:  

Mesh:

Year:  2004        PMID: 15529839

Source DB:  PubMed          Journal:  Am Surg        ISSN: 0003-1348            Impact factor:   0.688


  3 in total

1.  Study of the performance of a novel 1 mm resolution dual-panel PET camera design dedicated to breast cancer imaging using Monte Carlo simulation.

Authors:  Jin Zhang; Peter D Olcott; Garry Chinn; Angela M K Foudray; Craig S Levine
Journal:  Med Phys       Date:  2007-02       Impact factor: 4.071

Review 2.  Accuracy of ultrasound-guided, large-core needle breast biopsy.

Authors:  G Schueller; C Schueller-Weidekamm; T H Helbich
Journal:  Eur Radiol       Date:  2008-04-15       Impact factor: 5.315

3.  Contrast-Enhanced Ultrasound Guided Biopsy of Undetermined Abdominal Lesions: A Multidisciplinary Decision-Making Approach.

Authors:  Feng Mao; Yi Dong; Zhengbiao Ji; Jiaying Cao; Wen-Ping Wang
Journal:  Biomed Res Int       Date:  2017-01-04       Impact factor: 3.411

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.