Literature DB >> 15528955

Nonhabitual seizures in patients with implanted subdural electrodes.

Kostas N Fountas1, Donald W King, Patrick D Jenkins, Joseph R Smith.   

Abstract

The implantation of subdural electrodes has been widely employed in the invasive monitoring of patients with medically refractory epilepsy. The use of subdural electrodes, though, has been associated with rare but occasionally troublesome complications. We report the occurrence of nonhabitual seizures after implanting subdural grid electrodes. Among 57 patients diagnosed with medically refractory epilepsy who were evaluated in our department over a 12-month period, 21 patients underwent craniotomy for subdural grid/strip electrode implantation. Subdural grids and strips (AdTech, Racine, Wisc., USA) were used for continuous video EEG monitoring. In 3 patients, during subdural monitoring, consistent nonhabitual seizure activity was recorded. This was both clinically and electrographically different than the patients' habitual seizures. The patients' nonhabitual seizures disappeared postoperatively after removing the implanted electrodes. The occurrence of nonhabitual seizures, though quite rare, could lead to mislocalization of an epileptogenic focus. This complication might be the result of direct mechanical cortical irritation or chemical irritation caused by blood breakdown products. The occurrence of nonhabitual seizures comes to add itself to the existing list of complications associated with employment of subdural electrodes for invasive monitoring. 2004 S. Karger AG, Basel.

Entities:  

Mesh:

Year:  2004        PMID: 15528955     DOI: 10.1159/000081881

Source DB:  PubMed          Journal:  Stereotact Funct Neurosurg        ISSN: 1011-6125            Impact factor:   1.875


  3 in total

Review 1.  Placement of subdural grids in pediatric patients: technique and results.

Authors:  William E Bingaman; Juan Bulacio
Journal:  Childs Nerv Syst       Date:  2014-10-09       Impact factor: 1.475

2.  Intracranial EEG fluctuates over months after implanting electrodes in human brain.

Authors:  Hoameng Ung; Steven N Baldassano; Hank Bink; Abba M Krieger; Shawniqua Williams; Flavia Vitale; Chengyuan Wu; Dean Freestone; Ewan Nurse; Kent Leyde; Kathryn A Davis; Mark Cook; Brian Litt
Journal:  J Neural Eng       Date:  2017-09-01       Impact factor: 5.379

3.  Diagnostic outcome of surgical revision of intracranial electrode placements for seizure localization.

Authors:  Ricky W Lee; Gregory A Worrell; W Richard Marsh; Gregory D Cascino; Nicholas M Wetjen; Fredric B Meyer; Elaine C Wirrell; Elson L So
Journal:  J Clin Neurophysiol       Date:  2014-06       Impact factor: 2.177

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.