| Literature DB >> 15527500 |
Guicheng Zhang1, Jeffery Spickett, Krassi Rumchev, Andy H Lee, Stephen Stick.
Abstract
BACKGROUND: The home is the predominant environment for exposure to many environmental irritants such as air pollutants and allergens. Exposure to common indoor irritants including volatile organic compounds, formaldehyde and nitrogen dioxide, may increase the risk of snoring for children. The aim of this study was to investigate domestic environmental factors associated with snoring in children.Entities:
Mesh:
Substances:
Year: 2004 PMID: 15527500 PMCID: PMC535337 DOI: 10.1186/1465-9921-5-19
Source DB: PubMed Journal: Respir Res ISSN: 1465-9921
Prevalence of infrequent and habitual snoring by age and gender
| Gender | |||||||
| Boys | Girls | ||||||
| n | % | n | % | P | |||
| Infrequent snoring | 130 | 25.9 | 118 | 24.4 | >0.05 | ||
| Habitual snoring | 82 | 16.3 | 69 | 14.3 | >0.05 | ||
| Age | |||||||
| < 7 years | 7 – 9 years | > 9 years | P | ||||
| n | % | n | % | n | % | ||
| Infrequent snoring | 77 | 26.6 | 70 | 25.5 | 100 | 24.0 | >0.05 |
| Habitual snoring | 58 | 20.1 | 42 | 15.3 | 51 | 12.2 | 0.03 |
Snoring and respiratory symptoms, asthma and other allergic conditions
| Non-snoring | Infrequent snoring | Habitual snoring | |||||
| n | % | n | % | n | % | P | |
| Phlegm with a cold | 145 | 24.7 | 97 | 39.1 | 66 | 44.0 | <0.001 |
| Phlegm without a cold | 38 | 6.5 | 31 | 12.5 | 25 | 16.6 | <0.001 |
| Chronic productive cough | 12 | 2.1 | 13 | 5.2 | 14 | 9.3 | <0.001 |
| Wheeze during or after exercise | 71 | 12.1 | 54 | 21.8 | 37 | 24.5 | <0.001 |
| Wheeze without exercise | 47 | 8.0 | 27 | 10.9 | 26 | 17.2 | <0.001 |
| Any current wheeze | 110 | 18.8 | 83 | 33.5 | 59 | 39.3 | <0.001 |
| Dry cough at night without a cold | 134 | 22.9 | 98 | 39.7 | 66 | 43.7 | <0.001 |
| Ever asthma | 140 | 23.9 | 86 | 34.7 | 56 | 37.1 | <0.001 |
| Current asthma | 83 | 14.3 | 62 | 25.0 | 36 | 24.2 | <0.001 |
| Allergic rhinitis or hay fever | 217 | 37.6 | 123 | 49.6 | 92 | 61.7 | <0.001 |
Snoring and household characteristics
| Non-snoring | Infrequent snoring | Habitual snoring | ||||||
| N | n | % | n | % | n | % | P | |
| Type of cooking | ||||||||
| Gas cooking | 565 | 331 | 57.5 | 155 | 63.0 | 79 | 53.0 | >0.05 |
| Electric cooking | 221 | 142 | 24.7 | 43 | 17.5 | 36 | 24.2 | >0.05 |
| Gas and electric cooking | 185 | 103 | 17.9 | 48 | 19.5 | 34 | 22.8 | >0.05 |
| Dampness at home | ||||||||
| Damp patch | 85 | 49 | 8.5 | 25 | 10.2 | 11 | 7.5 | >0.05 |
| Condensation | 273 | 153 | 26.7 | 74 | 30.2 | 46 | 30.7 | >0.05 |
| Mould | 167 | 92 | 18.1 | 42 | 19.2 | 33 | 24.1 | >0.05 |
| Other characteristics | ||||||||
| Carpet in child's bedroom | 827 | 491 | 83.9 | 208 | 84.2 | 128 | 85.3 | >0.05 |
| Smoking household | 432 | 235 | 41.3 | 113 | 46.3 | 84 | 56.4 | 0.004 |
| Pet at home | 787 | 474 | 82.7 | 203 | 83.2 | 110 | 73.3 | 0.022 |
Snoring and indoor pollutants
| Houses of non-snoring children | Houses of snoring children | |||||||||
| n1 | GM2 | Min | Max | n1 | GM2 | Min | Max | P | ||
| TVOCs | ||||||||||
| Living room | Summer | 47 | 11 | 1 | 254 | 32 | 15 | 2 | 204 | >0.05 |
| Winter | 52 | 15 | 1 | 247 | 34 | 22 | 1 | 575 | >0.05 | |
| HCHO | ||||||||||
| Living room | Summer | 48 | 7 | ND | 34 | 32 | 6 | ND | 26 | >0.05 |
| Winter | 51 | 15 | 2 | 92 | 33 | 19 | ND | 92 | >0.05 | |
| Bedroom | Summer | 48 | 9 | ND | 126 | 32 | 8 | ND | 47 | >0.05 |
| Winter | 49 | 16 | 2 | 84 | 33 | 18 | 2 | 98 | >0.05 | |
| NO2 | ||||||||||
| Living room | Summer | 48 | 37 | 11 | 244 | 32 | 41 | 8 | 511 | >0.05 |
| Winter | 51 | 38 | 9 | 314 | 32 | 48 | 6 | 345 | >0.05 | |
| Bedroom | Summer | 48 | 32 | 6 | 293 | 32 | 31 | 6 | 199 | >0.05 |
| Winter | 50 | 33 | 6 | 267 | 32 | 56 | 8 | 511 | 0.015 | |
ND = not detectable
1 Missing data or lost to follow-up present
2 Geometric mean of pollutant concentration (μg/m3)