Literature DB >> 15526200

Augmented repair of acute Achilles tendon ruptures using gastrocnemius-soleus fascia.

Agustin Garabito1, Jesus Martinez-Miranda, Joaquin Sanchez-Sotelo.   

Abstract

Fifty-four consecutive acute Achilles tendon ruptures were treated with end-to-end suture augmented with gastrocnemius fascial flaps. Surgery was performed within 24 h. Mean patient age was 35 (23-57) years, and 46 were men. Mean follow-up time was 4.8 (2-8) years. At follow-up, the mean visual analogue scale for pain was 0.49, and the mean AOFAS ankle-hindfoot score was 95 (74-100) points. Fifty-three patients were able to stand on their tiptoes for 30 s and perform repeated toe raises, and 50 patients were able to perform single-limb hopping. Complications included rerupture in one case, deep infection in three cases, delayed wound healing in eight cases, and deep venous thrombosis in one case. Reconstruction of acute ruptures of the Achilles tendon augmented with gastrocnemius-soleus fascial flaps provided a good outcome but was associated with a high complication rate.

Entities:  

Mesh:

Year:  2004        PMID: 15526200      PMCID: PMC3456949          DOI: 10.1007/s00264-004-0598-2

Source DB:  PubMed          Journal:  Int Orthop        ISSN: 0341-2695            Impact factor:   3.075


  22 in total

1.  Percutaneous repair of ruptured tendo Achillis.

Authors:  A S Vivaldi
Journal:  J Bone Joint Surg Br       Date:  2000-05

2.  Percutaneous repair of the ruptured tendo Achillis.

Authors:  J M Webb; G C Bannister
Journal:  J Bone Joint Surg Br       Date:  1999-09

3.  Anatomy of the sural nerve and its relation to the Achilles tendon.

Authors:  J Webb; N Moorjani; M Radford
Journal:  Foot Ankle Int       Date:  2000-06       Impact factor: 2.827

4.  Gait abnormalities following resection of talocalcaneal coalition.

Authors:  H B Kitaoka; M A Wikenheiser; W J Shaughnessy; K N An
Journal:  J Bone Joint Surg Am       Date:  1997-03       Impact factor: 5.284

5.  Percutaneous vs. open repair of the ruptured Achilles tendon--a prospective randomized controlled study.

Authors:  J Lim; R Dalal; M Waseem
Journal:  Foot Ankle Int       Date:  2001-07       Impact factor: 2.827

6.  Augmented repair of acute Achilles tendon ruptures.

Authors:  R A Zell; V M Santoro
Journal:  Foot Ankle Int       Date:  2000-06       Impact factor: 2.827

7.  Limited open repair of Achilles tendon ruptures: a technique with a new instrument and findings of a prospective multicenter study.

Authors:  Mathieu Assal; Maximilien Jung; Richard Stern; Pascal Rippstein; Marino Delmi; Pierre Hoffmeyer
Journal:  J Bone Joint Surg Am       Date:  2002-02       Impact factor: 5.284

8.  End-to-end operative repair of Achilles tendon rupture.

Authors:  J J Soldatis; D B Goodfellow; J H Wilber
Journal:  Am J Sports Med       Date:  1997 Jan-Feb       Impact factor: 6.202

9.  Augmented repair of Achilles tendon ruptures.

Authors:  M Fernández-Fairén; C Gimeno
Journal:  Am J Sports Med       Date:  1997 Mar-Apr       Impact factor: 6.202

10.  Surgical treatment of ruptures of the Achilles tendon: a review of long-term results.

Authors:  M Krueger-Franke; C H Siebert; S Scherzer
Journal:  Br J Sports Med       Date:  1995-06       Impact factor: 13.800

View more
  4 in total

1.  Repair of experimental Achilles tenotomy with porcine renal capsule material in a rat model.

Authors:  M A Suckow; J P Hodde; W R Wolter; M C Hiles
Journal:  J Mater Sci Mater Med       Date:  2007-02-01       Impact factor: 4.727

2.  Augmented repair of acute tendo Achilles ruptures with gastrosoleus turn down flap.

Authors:  Murat Demirel; Egemen Turhan; Ferit Dereboy; Tarik Yazar
Journal:  Indian J Orthop       Date:  2011-01       Impact factor: 1.251

3.  Arthroscopic Flexor Halluces Longus Transfer and Percutaneous Achilles Tendon Repair for Distal Traumatic Ruptures.

Authors:  David Campillo-Recio; Maximiliano Ibañez; Hector Hormigo-Garcia; Eugenio Jimeno-Torres; Jesus Vilá-Rico; Gloria Alberti-Fito
Journal:  Arthrosc Tech       Date:  2021-10-06

4.  Return to play post-Achilles tendon rupture: a systematic review and meta-analysis of rate and measures of return to play.

Authors:  Jennifer A Zellers; Michael R Carmont; Karin Grävare Silbernagel
Journal:  Br J Sports Med       Date:  2016-06-03       Impact factor: 13.800

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.