Literature DB >> 1552572

Computer-assisted realignment of light micrograph images from consecutive section series of cat cerebral cortex.

M Rydmark1, T Jansson, C H Berthold, T Gustavsson.   

Abstract

Two computer- and image-analysis-based procedures for realignment of images of consecutive light micrographs of nerve tissue (cat motor cortex) have been developed. One procedure (CENT) was interactive, employing the subjective overall 'best fit' of two images to each other and the other (AUTOCENT) was based on an automatic comparison of two images (image thresholding and binary comparison). Images of light micrographs of several hundred consecutive sections were realigned using the interactive and the automatic methods. The interactive procedure was easy to use; realignment of an image took only a few minutes in the hands of an experienced operator and should be easy to implement on commercially available smaller computers like PCs and workstations, but the realignment was possibly disturbed by the operator's subjective expectancy of regular forms. The automatic procedure realigned 1-4 images per hour, might be implemented on smaller computers if the programming is made more efficient, was probably objective and restored the 'true position of images'.

Mesh:

Year:  1992        PMID: 1552572     DOI: 10.1111/j.1365-2818.1992.tb04303.x

Source DB:  PubMed          Journal:  J Microsc        ISSN: 0022-2720            Impact factor:   1.758


  5 in total

1.  A new method of three-dimensional computer assisted reconstruction of the developing biliary tract.

Authors:  M Prudhomme; R Gaubert-Cristol; M Jaeger; P De Reffye; G Godlewski
Journal:  Surg Radiol Anat       Date:  1999       Impact factor: 1.246

2.  Computer-aided three-dimensional reconstruction of main vessels in hemangiomas.

Authors:  Guanghuan Wang; Jun Zhong; Jianhong Li; Xuan Zhang; Shouxing Duan; Maxian Fu; Fusheng Wang; Xuewu Jiang
Journal:  Int J Clin Exp Med       Date:  2015-02-15

3.  A computerised technique for morphometry and 3D reconstruction of embryological structures.

Authors:  L A Arraez-Aybar; J R Mérida-Velasco; J Rodriguez-Vazquez; J Jiménez-Collado
Journal:  Surg Radiol Anat       Date:  1994       Impact factor: 1.246

4.  Three-dimensional computer-assisted reconstruction of ductal plate in the rat embryo (Carnegie stages 19-23).

Authors:  G Godlewski; J Gaubert; R Gaubert-Cristol; M Dauzat; F Aldréa; M Prudhomme
Journal:  Surg Radiol Anat       Date:  2004-10       Impact factor: 1.246

5.  Enhancement of histological volumes through averaging and their use for the analysis of magnetic resonance images.

Authors:  Xia Li; Thomas E Yankeelov; Glenn D Rosen; John C Gore; Benoit M Dawant
Journal:  Magn Reson Imaging       Date:  2008-09-10       Impact factor: 2.546

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.