Literature DB >> 15525612

Arousal with iv epinephrine depends on the depth of anesthesia.

Hye-Won Shin1, Young-Jun Ban, Hye-Won Lee, Hae-Ja Lim, Suk-Min Yoon, Seong-Ho Chang.   

Abstract

PURPOSE: To investigate whether the depth of anesthesia affects the change in the bispectral index (BIS) caused by iv epinephrine during propofol anesthesia.
METHODS: Forty women undergoing elective lower abdominal surgery received a propofol target controlled infusion (TCI) to maintain a modified Observer's Assessment of Alertness/Sedation (OAA/S) score of 2 (sedation period). Subsequently anesthesia was induced with propofol TCI 5 mug.mL(-1) and rocuronium 0.9 mg.kg(-1), and propofol continued so as to maintain general anesthesia at a BIS of 50 (general anesthesia period). Intravenous epinephrine at a dose of 10 mug.5 mL(-1) in normal saline (epinephrine group, n = 20) or normal saline 5 mL (control group, n = 20) was administered during both periods. The BIS, mean arterial pressure (MAP) and heart rate (HR) were measured immediately before, and one, two, three, four, six, eight, and ten minutes after injection. The modified OAA/S scale was evaluated during the sedation period.
RESULTS: There was no significant change in the modified OAA/S scale, BIS, or hemodynamic variables compared to preinjection values during either sedation or general anesthesia in the control group. Intravenous epinephrine increased the BIS and modified OAA/S scale during sedation, but there was no increase in BIS during general anesthesia. Increases in HR and MAP were observed during both periods after iv epinephrine.
CONCLUSION: Intravenous epinephrine 10 mug resulted in an arousal effect and an increase in BIS during sedation, but did not change the BIS during general anesthesia. These results suggest that the arousal effect of iv epinephrine during propofol anesthesia depends on anesthetic depth.

Entities:  

Mesh:

Substances:

Year:  2004        PMID: 15525612     DOI: 10.1007/BF03018884

Source DB:  PubMed          Journal:  Can J Anaesth        ISSN: 0832-610X            Impact factor:   5.063


  4 in total

1.  BIS values during resuscitation: the role of the suppression ratio (case report).

Authors:  Agnes Declerck; Ngai Liu; Thierry Chazot; Marc Fischler
Journal:  J Clin Monit Comput       Date:  2009-08-21       Impact factor: 2.502

2.  Effects of phenytoin therapy on bispectral index and haemodynamic changes following induction and tracheal intubation.

Authors:  Parmod K Bithal; Mihir P Pandia; Rajendra S Chouhan; Hemanshu Prabhakar; Girija P Rath; Hari Hara Dash; Manish K Marda
Journal:  Indian J Anaesth       Date:  2009-04

3.  Hemodynamic and bispectral index changes following skull pin attachment with and without local anesthetic infiltration of the scalp.

Authors:  Parmod Kumar Bithal; Mihir Prakash Pandia; Rajender Singh Chouhan; Deepak Sharma; Hemant Bhagat; Hari Hara Dash; Rajni Arora
Journal:  J Anesth       Date:  2007-08-01       Impact factor: 2.078

4.  Does a single dose of intravenous nicardipine or nimodipine affect the bispectral index following rapid sequence intubation?

Authors:  Jeong Jin Lee; Jie Ae Kim; Hyun Joo Ahn; Jin-Kyoung Kim; Mikyung Yang; Soo Joo Choi; Hyun-Soo Kim; Soo Hyun Yang
Journal:  Korean J Anesthesiol       Date:  2010-10-21
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.