A prospective, randomised, double-blind study of comparative efficacy of immediate versus daily cleaning of stethoscope using 66% ethyl alcohol.

Ramesh C Parmar1, Chayya C Valvi, Poonam Sira, Jaishree R Kamat.   

Abstract

OBJECTIVE: Studies have demonstrated frequent contamination of stethoscope and usefulness of different disinfectants. Albeit, studies on the precise mode of cleaning and frequency of cleaning are lacking. This study was carried out to determine efficacy of 66% ethyl alcohol as disinfectant, rate of recontamination without cleaning and benefits of daily versus immediate cleaning.
METHODOLOGY: Prospective, randomised, double blind study of 100 stethoscopes. Four cultures were obtained: before cleaning (Group A), immediately after cleaning with 66% ethyl alcohol (Group B), at the end of 4 days without cleaning (Group C) and at the end of 4 days after cleaning once a day (Group D). Samples were analysed using standard microbiological methods and Colony-forming unit (CFU) count and residual microorganism was computed for all the positive cultures. Medical staff was asked about the cleaning practices. Statistical analysis was carried out using 95% confidence interval and Chi-square test.
RESULTS: 90% of the stethoscopes were contaminated with one or more microorganisms. Immediate cleaning and daily cleaning were associated with a significant reduction in the rate of contamination to 28% and 25% respectively. CFU count in groups B and D dropped to less than 10 in 75% and 84.7%, while the mean residual rates were 5.2% and 3.65% respectively. Groups B and D showed no statistically significant difference in terms of efficacy of disinfection.
CONCLUSIONS: 66% ethyl alcohol is an effective disinfectant. The effects of immediate cleaning and cleaning once a day on residual flora on the diaphragm of stethoscope is comparable.

Entities:  

Mesh:

Substances:

Year:  2004        PMID: 15523163

Source DB:  PubMed          Journal:  Indian J Med Sci        ISSN: 0019-5359


  8 in total

1.  A simple effective clean practice protocol significantly improves hand decontamination and infection control measures in the acute surgical setting.

Authors:  D P J Howard; C Williams; S Sen; A Shah; J Daurka; R Bird; A Loh; A Howard
Journal:  Infection       Date:  2008-12-05       Impact factor: 3.553

2.  Bacterial contamination, bacterial profile and antimicrobial susceptibility pattern of isolates from stethoscopes at Jimma University Specialized Hospital.

Authors:  Teklu Shiferaw; Getenet Beyene; Tesfaye Kassa; Tsegaye Sewunet
Journal:  Ann Clin Microbiol Antimicrob       Date:  2013-12-13       Impact factor: 3.944

3.  Aseptic Stethoscope Barriers Prevent C difficile Transmission In Vitro.

Authors:  W Frank Peacock; Sarathi Kalra; Rajiv S Vasudevan; Francesca Torriani
Journal:  Mayo Clin Proc Innov Qual Outcomes       Date:  2021-01-13

4.  Stethoscope Hygiene: Practice and Attitude of Medical Students.

Authors:  Tatjana Gazibara; Sanja Radovanovic; Gorica Maric; Biljana Rancic; Darija Kisic-Tepavcevic; Tatjana Pekmezovic
Journal:  Med Princ Pract       Date:  2015-07-22       Impact factor: 1.927

5.  Stethoscope disinfection is rarely done in Ethiopia: What are the associated factors?

Authors:  Biniyam Sahiledengle
Journal:  PLoS One       Date:  2019-06-27       Impact factor: 3.240

6.  Non-critical healthcare tools as a potential source of healthcare-acquired bacterial infections in eastern Ethiopia: A hospital-based cross-sectional study.

Authors:  Fitsum Weldegebreal; Desalegn Admassu; Dereje Meaza; Mulatu Asfaw
Journal:  SAGE Open Med       Date:  2019-01-02

7.  Hey Doctor! Did You Wash Your Smartphone?

Authors:  Craig S Brown; Ben E Biesterveld; Seth A Waits
Journal:  J Gen Intern Med       Date:  2020-04-20       Impact factor: 5.128

Review 8.  Methods of Disinfecting Stethoscopes: Systematic Review.

Authors:  Margherita Napolitani; Daiana Bezzini; Fulvio Moirano; Corrado Bedogni; Gabriele Messina
Journal:  Int J Environ Res Public Health       Date:  2020-03-13       Impact factor: 3.390

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.