Literature DB >> 15522608

Regeneration of ethyl parathion antibodies for repeated use in immunosensor: a study on dissociation of antigens from antibodies.

V B Kandimalla1, N S Neeta, N G Karanth, M S Thakur, K R Roshini, B E A Rani, A Pasha, N G K Karanth.   

Abstract

Reliable analysis using an immunosensor strongly depends on the specificity, activity, and sensitivity of the antibody. Immobilization of antibody on the solid matrix enables its repeated use, for which it is required to dissociate the antigens and antigen-enzyme conjugate from the immobilized antibody matrix after each use and while doing so, a maximum retention of activity and specificity are crucial requirements. In the present investigation, on the development of an immunosensor for the organophosphorus pesticide ethyl parathion (EP) using EP antibodies, different dissociating agents such as organic solvents, detergents and acidic buffers, that is, dimethyl sulphoxide (DMSO), Tween-20, cetyl trimethylammonium bromide (CTAB), methanol, chloroform, guanidium chloride (GdmCl), glycine-HCl (Gly-HCl) buffer in the pH range of 1.5-3.0, pierce buffer and combination of DMSO and methanol in phosphate buffer and Gly-HCl buffer and salts like NaCl and MgCl2 were used. Generally about 50-60% dissociation was obtained with some degree of denaturation of the antibody immobilized on the sepharose matrix. However, 1% DMSO in combination with 0.2 M Gly-HCl buffer at a pH of 2.3 showed 97% dissociation and the immobilized antibody retained sufficient activity to carry out 14 reproducible assays for EP.

Entities:  

Mesh:

Substances:

Year:  2004        PMID: 15522608     DOI: 10.1016/j.bios.2004.03.027

Source DB:  PubMed          Journal:  Biosens Bioelectron        ISSN: 0956-5663            Impact factor:   10.618


  10 in total

1.  Regeneration of Arrayed Gold Microelectrodes Equipped for a Real-Time Cell Analyzer.

Authors:  Zhihui Xu; Yiyan Song; Huijun Jiang; Yan Kong; Xiaoming Li; Jin Chen; Yuan Wu
Journal:  J Vis Exp       Date:  2018-03-12       Impact factor: 1.355

2.  Tumor delivery of antisense oligomer using trastuzumab within a streptavidin nanoparticle.

Authors:  Yi Wang; Xinrong Liu; Ling Chen; Dengfeng Cheng; Mary Rusckowski; Donald J Hnatowich
Journal:  Eur J Nucl Med Mol Imaging       Date:  2009-12       Impact factor: 9.236

3.  Label-free flow-enhanced specific detection of Bacillus anthracis using a piezoelectric microcantilever sensor.

Authors:  John-Paul McGovern; Wan Y Shih; Richard Rest; Mitali Purohit; Yognandan Pandya; Wei-Heng Shih
Journal:  Analyst       Date:  2008-02-29       Impact factor: 4.616

4.  Quantitative evaluation of sensitivity and selectivity of multiplex nanoSPR biosensor assays.

Authors:  Chenxu Yu; Joseph Irudayaraj
Journal:  Biophys J       Date:  2007-07-27       Impact factor: 4.033

5.  A rapid method to regenerate piezoelectric microcantilever sensors (PEMS).

Authors:  LiNa Loo; Wei Wu; Wan Y Shih; Wei-Heng Shih; Hossein Borghaei; Kambiz Pourrezaei; Gregory P Adams
Journal:  Sensors (Basel)       Date:  2011       Impact factor: 3.576

6.  Recent Advances Incorporating Superparamagnetic Nanoparticles into Immunoassays.

Authors:  Yeonjeong Ha; Saebom Ko; Ijung Kim; Yimin Huang; Kishore Mohanty; Chun Huh; Jennifer A Maynard
Journal:  ACS Appl Nano Mater       Date:  2018-01-31

7.  Sensing of COVID-19 Antibodies in Seconds via Aerosol Jet Nanoprinted Reduced-Graphene-Oxide-Coated 3D Electrodes.

Authors:  Md Azahar Ali; Chunshan Hu; Sanjida Jahan; Bin Yuan; Mohammad Sadeq Saleh; Enguo Ju; Shou-Jiang Gao; Rahul Panat
Journal:  Adv Mater       Date:  2020-12-22       Impact factor: 32.086

8.  N protein-based ultrasensitive SARS-CoV-2 antibody detection in seconds via 3D nanoprinted, microarchitected array electrodes.

Authors:  Md Azahar Ali; Chunshan Hu; Fei Zhang; Sanjida Jahan; Bin Yuan; Mohammad S Saleh; Shou-Jiang Gao; Rahul Panat
Journal:  J Med Virol       Date:  2022-01-26       Impact factor: 20.693

9.  Prefab Hollow Glass Microsphere-Based Immunosensor with Liquid Crystal Sensitization for Acute Myocardial Infarction Biomarker Detection.

Authors:  Panpan Niu; Junfeng Jiang; Kun Liu; Shuang Wang; Tianhua Xu; Ziyihui Wang; Tong Wang; Xuezhi Zhang; Zhenyang Ding; Yize Liu; Tiegen Liu
Journal:  Biosensors (Basel)       Date:  2022-06-22

10.  Flexible and Printed Electrochemical Immunosensor Coated with Oxygen Plasma Treated SWCNTs for Histamine Detection.

Authors:  Bajramshahe Shkodra; Biresaw Demelash Abera; Giuseppe Cantarella; Ali Douaki; Enrico Avancini; Luisa Petti; Paolo Lugli
Journal:  Biosensors (Basel)       Date:  2020-04-10
  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.