Literature DB >> 15518226

Colorimetric analysis of four editions of the Hardy-Rand-Rittler pseudoisochromatic tests.

Stephen J Dain1.   

Abstract

At the Göttingen meeting of the International Colour Vision Society, I reported on a comparison of the second edition of the American Optical Hardy-Rand-Rittler Pseudoisochromatic plates (AO HRR) with the Richmond Products third edition of the same test and concluded that the chromaticities were exceptionally poorly matched and that the new edition was a "pale imitation of the real thing" (unpublished). This conclusion led to our abandoning a clinical trial. In 2002, Richmond Products has published a fourth edition and, in 2003, Waggoner has published a modified HRR with additional (Ishihara style) plates and the tetartan confusion figures removed. As a precursor to any clinical trial, the colors used in the plates have been measured and comparisons drawn between the four editions. While the two most recent editions much more closely resemble the original AO HRR and the chromaticities are much better aligned on the dichromatic confusion lines, the excitation purities (and therefore the degree of difficulty) of the plates are less well matched in the Richmond Products editions. In addition, there is a significant degree of metamerism in the third edition and Waggoner edition that makes variations in illuminant more critical to performance.

Entities:  

Mesh:

Year:  2004        PMID: 15518226     DOI: 10.1017/s0952523804213475

Source DB:  PubMed          Journal:  Vis Neurosci        ISSN: 0952-5238            Impact factor:   3.241


  3 in total

1.  Comparison between Hardy-Rand-Rittler 4th edition and Ishihara color plate tests for detection of dyschromatopsia in optic neuropathy.

Authors:  Ruth Huna-Baron; Yoseph Glovinsky; Zohar Habot-Wilner
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2012-06-13       Impact factor: 3.117

2.  The Impact of Concurrent Antiretroviral Therapy and MDR-TB Treatment on Adverse Events.

Authors:  Jonathan P Smith; Neel R Gandhi; N Sarita Shah; Koleka Mlisana; Pravi Moodley; Brent A Johnson; Salim Allana; Angela Campbell; Kristin N Nelson; Iqbal Master; James C M Brust
Journal:  J Acquir Immune Defic Syndr       Date:  2020-01-01       Impact factor: 3.771

3.  Color-discrimination threshold determination using pseudoisochromatic test plates.

Authors:  Kaiva Jurasevska; Maris Ozolinsh; Sergejs Fomins; Ausma Gutmane; Brigita Zutere; Anete Pausus; Varis Karitans
Journal:  Front Psychol       Date:  2014-11-27
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.