Literature DB >> 15517573

Utility of automated counting to determine absolute neutrophil counts and absolute phagocyte counts for pediatric cancer treatment protocols.

Nobuko Hijiya1, Mihaela Onciu, Scott C Howard, Zhe Zhang, Cheng Cheng, John T Sandlund, Emily P Kyzer, Fred G Behm, Ching-Hon Pui.   

Abstract

BACKGROUND: Absolute neutrophil counts (ANCs) and absolute phagocyte counts (APCs) are used to guide cancer treatment. Although automated counting could replace manual counting, data showing correlations are lacking. By analyzing blood samples from children undergoing cancer treatment, the authors determined whether ANCs and APCs obtained by automated methods correlated positively with ANCs and APCs obtained manually.
METHODS: The authors analyzed 3640 consecutive peripheral blood samples. Leukocyte counts determined by Beckman-Coulter Gen-S or HmX analyzers (Beckman-Coulter, Miami, FL) were used to calculate counts obtained by automated or manual methods. Automated differential counts were obtained by automated analyzers and manual differential counts were performed by medical technologists. Counts underwent linear regression analysis. The authors evaluated 5 cutoff values for ANCs and APCs commonly used in decision-making related to cancer treatment: 300/muL, 500/muL, 750/muL, 1000/muL, and 1500/muL. Manually determined ANCs and APCs served as standards to determine the sensitivity, specificity, positive and negative predictive values, and kappa coefficient for automated counting.
RESULTS: R(2) values were 0.81 for ANCs determined by manual and automated methods and 0.84 for APCs determined by both methods. The specificity of the automated method was > 90% for all ranges of ANCs and APCs, except one (APCs < 300/muL). There was excellent agreement (kappa > 0.9) between ANCs determined by manual and automated methods and APCs calculated by both methods.
CONCLUSIONS: Automated methods of determining ANCs and APCs for children undergoing cancer treatment were reliable and can replace manual counting. Blood smear examination to validate ANCs and APCs determined by automated methods was needed only in selected cases. (c) 2004 American Cancer Society

Entities:  

Mesh:

Year:  2004        PMID: 15517573     DOI: 10.1002/cncr.20677

Source DB:  PubMed          Journal:  Cancer        ISSN: 0008-543X            Impact factor:   6.860


  3 in total

1.  Validity of Selected WBC Differentiation Flags in Sysmex XT-1800i.

Authors:  Parya Bameni Moghaddam; Fatemeh Mahjoub; Amirhossein Emami; Alireza Abdollahi
Journal:  Iran J Pathol       Date:  2016

2.  A flow cytometric method for determination of the blood neutrophil fraction in rats.

Authors:  Spela Skrajnar; Marija Anzur Lasnik; Apolonija Bedina Zavec
Journal:  J Am Assoc Lab Anim Sci       Date:  2009-03       Impact factor: 1.232

3.  Immature Reticulocyte Fraction and Absolute Neutrophil Count as Predictor of Hemopoietic Recovery in Patients with Acute Lymphoblastic Leukemia on Remission Induction Chemotherapy.

Authors:  Shan E Rauf; Saleem Ahmed Khan; Nadir Ali; Nabeel Khan Afridi; Maria Haroon; Ammara Arslan
Journal:  Turk J Haematol       Date:  2015-08-06       Impact factor: 1.831

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.