Literature DB >> 15516132

Dual microelectrodes for distance control and detection of nitric oxide from endothelial cells by means of scanning electrochemical microscope.

Sonnur Isik1, Mathieu Etienne, Joshua Oni, Andrea Blöchl, Sabine Reiter, Wolfgang Schuhmann.   

Abstract

Dual Pt disk microelectrodes consisting of a 10-microm distance sensor and a 50-microm nitric oxide sensor were prepared. The 50-microm electrode was modified with Ni(4-N-tetramethyl)pyridyl porphyrin enclosed in the polymer network of a negatively charged electrodeposition paint. This paint prevented the dissolution of the otherwise soluble porphyrin in the aqueous test medium due to charge interactions. It also denied negatively charged ions in the analyte solution access to the electrode surface by electrostatic repulsion, thereby preventing interference from anions such as nitrite, nitrate, and ascorbate. With the aid of a scanning electrochemical microscope, it was possible to use the distance sensor by recording the negative feedback effect on the reduction of molecular oxygen to "guide" the nitric oxide sensor to various known distances from a layer of adherently growing human umbilical vein endothelial cells for the detection of nitric oxide released from the cells upon stimulation with bradykinin. The use of the distance sensor made it possible to preserve the integrity of the adherently growing cells concomitantly with the modified electrode by preventing the deterioration of the modifying layer during the distance adjustment step.

Entities:  

Mesh:

Substances:

Year:  2004        PMID: 15516132     DOI: 10.1021/ac049182w

Source DB:  PubMed          Journal:  Anal Chem        ISSN: 0003-2700            Impact factor:   6.986


  4 in total

1.  Selective and Sensocompatible Electrochemical Nitric Oxide Sensor with a Bilaminar Design.

Authors:  Micah D Brown; Mark H Schoenfisch
Journal:  ACS Sens       Date:  2019-06-20       Impact factor: 7.711

2.  Direct, real-time measurement of shear stress-induced nitric oxide produced from endothelial cells in vitro.

Authors:  Allison M Andrews; Dov Jaron; Donald G Buerk; Patrick L Kirby; Kenneth A Barbee
Journal:  Nitric Oxide       Date:  2010-08-16       Impact factor: 4.427

3.  Fabrication, characterization, and functionalization of dual carbon electrodes as probes for scanning electrochemical microscopy (SECM).

Authors:  Kim McKelvey; Binoy Paulose Nadappuram; Paolo Actis; Yasufumi Takahashi; Yuri E Korchev; Tomokazu Matsue; Colin Robinson; Patrick R Unwin
Journal:  Anal Chem       Date:  2013-07-08       Impact factor: 6.986

Review 4.  Design and Electrochemical Study of Platinum-Based Nanomaterials for Sensitive Detection of Nitric Oxide in Biomedical Applications.

Authors:  Maduraiveeran Govindhan; Zhonggang Liu; Aicheng Chen
Journal:  Nanomaterials (Basel)       Date:  2016-11-14       Impact factor: 5.076

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.