Literature DB >> 15515589

Flow cytometric immunophenotype of canine lymph node aspirates.

D Gibson1, I Aubert, J P Woods, A Abrams-Ogg, S Kruth, R D Wood, D Bienzle.   

Abstract

Increasing availability of reagents able to distinguish subtypes of lymphocytes and other leukocytes has enabled greater understanding of lymphocyte biology and pathology in the dog. Lymphocytes in circulation most commonly are subjected to immunophenotypic assessment by flow cytometry, but needle aspirates of lymph nodes can be similarly suitable for immunophenotypic examination. In this investigation, the feasibility of immunophenotyping samples obtained by needle aspiration of lymph nodes from 32 dogs with no physical abnormalities and 6 dogs with lymphoma was determined. In addition, samples from 6 dogs were stored overnight at 4 degrees C and reanalyzed 24 hours later. For each sample, stained smear preparations were examined microscopically for lymphocyte morphology, neoplasia, and the presence of inflammatory cells. Expression of antigens on a corresponding sample of aspirated cells was determined by flow cytometric detection of antibody binding on a minimum of 10,000 events. The distribution of data was determined with Anderson-Darling tests, and reference intervals incorporating the central 95% of values were established. Adequate samples were obtained from 30 of 32 clinically normal dogs. Immunophenotypic results after 24 hours of storage were consistent with those obtained immediately after sampling. Reference intervals for lymphocyte subsets from normal dog lymph nodes were similar to the proportions of CD3+, CD4+, CD8+, and CD21+ lymphocytes found in blood. Aspirates of enlarged lymph nodes from dogs with lymphoma were readily classified by this technique. Aspiration of lymph nodes from dogs for comprehensive analysis by flow cytometry is feasible and applicable to immunophenotyping of lymphoma.

Entities:  

Mesh:

Substances:

Year:  2004        PMID: 15515589     DOI: 10.1892/0891-6640(2004)18<710:fciocl>2.0.co;2

Source DB:  PubMed          Journal:  J Vet Intern Med        ISSN: 0891-6640            Impact factor:   3.333


  4 in total

1.  Rapid, effective and user-friendly immunophenotyping of canine lymphoma using a personal flow cytometer.

Authors:  Stratos Papakonstantinou; Inese Berzina; Amanda Lawlor; Emma J O'Neill; Peter J O'Brien
Journal:  Ir Vet J       Date:  2013-04-01       Impact factor: 2.146

2.  Detection of clonal antigen receptor gene rearrangement in dogs with lymphoma by real-time polymerase chain reaction and melting curve analysis.

Authors:  Kathrin F A Langner; Alexa E Joetzke; Verena Nerschbach; Nina Eberle; Hans-Joachim Schuberth; Mirja Koy; Ingo Nolte; Daniela Betz
Journal:  BMC Vet Res       Date:  2014-01-03       Impact factor: 2.741

Review 3.  Flow Cytometry in the Diagnosis of Canine B-Cell Lymphoma.

Authors:  Fulvio Riondato; Stefano Comazzi
Journal:  Front Vet Sci       Date:  2021-03-19

4.  Flow Cytometric Assessment of Ki-67 Expression in Lymphocytes From Physiologic Lymph Nodes, Lymphoma Cell Populations and Remnant Normal Cell Populations From Lymphomatous Lymph Nodes.

Authors:  Barbara C Rütgen; Daniel Baumgartner; Andrea Fuchs-Baumgartinger; Antonella Rigillo; Ondřej Škor; Sabine E Hammer; Armin Saalmüller; Ilse Schwendenwein
Journal:  Front Vet Sci       Date:  2021-06-29
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.