Literature DB >> 15514196

Internal carotid artery stenosis measurement: comparison of 3D computed rotational angiography and conventional digital subtraction angiography.

Derek E Hyde1, Allan J Fox, Irene Gulka, Paul Kalapos, Don H Lee, David M Pelz, David W Holdsworth.   

Abstract

BACKGROUND AND
PURPOSE: Clinical trials have shown that carotid endarterectomy reduces stroke risk in symptomatic individuals with severe internal carotid artery (ICA) stenosis. As a result of these trials, digital subtraction angiography (DSA) became a standard of reference for ICA stenosis diagnosis. Newer 3D techniques provide a larger number of views than DSA, which may influence the estimated degree of stenosis. We evaluate this possibility by directly comparing stenosis grades from 3D computed rotational angiography (CRA) and DSA.
METHODS: As a prospective diagnostic study, we performed CRA and DSA on 26 consecutive symptomatic patients. Only 1 angiographic procedure was performed on normal asymptomatic arteries, yielding 42 arteries for comparison. Four neuroradiologists graded the CRA maximum intensity projections (MIPs) and DSA images, according to the North American Symptomatic Carotid Endarterectomy Trial guidelines. CRA studies included a search for the narrowest view by evaluating 60 MIPs generated at 3 degrees intervals and measurement of actual artery diameters. Artery diameters and stenosis grades were analyzed graphically; statistical significance was determined using a paired t test.
RESULTS: The mean difference of 1.2% (CI, -18%, 21%) between CRA and DSA stenosis grades was not statistically significant (P=0.55). Agreement of the optimal CRA viewing angle was limited, with an interobserver variability of 24+/-13 degrees . The interobserver variability of DSA and CRA stenosis grades, 9.1% (CI, 0%, 21%) and 9.4% (CI, 0%, 22%), respectively, was not significantly different (P=0.79).
CONCLUSIONS: CRA provides stenosis grades equivalent to DSA, as well as absolute measurements, providing a comparison for newer 3D techniques.

Entities:  

Mesh:

Year:  2004        PMID: 15514196     DOI: 10.1161/01.STR.0000147037.12223.d5

Source DB:  PubMed          Journal:  Stroke        ISSN: 0039-2499            Impact factor:   7.914


  4 in total

1.  Measurement error of percent diameter carotid stenosis determined by conventional angiography: implications for noninvasive evaluation.

Authors:  Joseph E Heiserman
Journal:  AJNR Am J Neuroradiol       Date:  2005-09       Impact factor: 3.825

Review 2.  Deep learning-based digital subtraction angiography image generation.

Authors:  Yufeng Gao; Yu Song; Xiangrui Yin; Weiwen Wu; Lu Zhang; Yang Chen; Wanyin Shi
Journal:  Int J Comput Assist Radiol Surg       Date:  2019-07-31       Impact factor: 2.924

3.  Ultrasonography evaluation on the protective effect of combination therapy of beraprost sodium and aspirin on arteries occlusion and stiffness in patients with type 2 diabetes mellitus - a prospective, randomized study.

Authors:  Xian Lin; Yuying Chen; Wan Lu; Jin Li; Li Fu; Jingyu Yin; Meng Ren; Li Yan; Chuan Yang
Journal:  BMC Endocr Disord       Date:  2022-04-02       Impact factor: 2.763

4.  An adaptive optimal viewing angle determination algorithm for TEVAR operation.

Authors:  Weiya Sun; Guanyu Yang; Yang Chen; Huazhong Shu
Journal:  BMC Med Imaging       Date:  2021-10-02       Impact factor: 1.930

  4 in total