Literature DB >> 15510846

Another blood supply to Adamkiewicz's artery.

Junetsu Akasaka1, Masahiro Sakurai, Kei Takase, Kiichiro Kumagai, Koichi Tabayashi.   

Abstract

A 76-year-old man underwent endovascular stent-grafting therapy for chronic aortic dissection. The preoperative multi detector row helical computed tomography (CT) revealed that Adamkiewicz's artery originated from the level of thoracic 9 intercostal artery. Intraoperative monitoring of motor evoked potentials showed no reduction of amplitude in the anterior tibialis muscle after deployment retrievable stent-graft. Postoperative CT showed that stent-graft blocked the ostium of intercostal arteries including Adamkiewicz's artery. On the other hand, the distal portion of the Adamkiewicz's artery was clearly enhanced. Our result showed that there is a collateral network supplying to Adamkiewicz's artery.

Entities:  

Mesh:

Year:  2004        PMID: 15510846     DOI: 10.1007/s11748-004-0039-6

Source DB:  PubMed          Journal:  Jpn J Thorac Cardiovasc Surg        ISSN: 1344-4964


  5 in total

1.  Demonstration of the artery of Adamkiewicz at multi- detector row helical CT.

Authors:  Kei Takase; Yoshihiro Sawamura; Kazumasa Igarashi; Yoshihiro Chiba; Kenichi Haga; Haruo Saito; Shoki Takahashi
Journal:  Radiology       Date:  2002-04       Impact factor: 11.105

2.  Preoperative spinal cord arteriography in aneurysmal disease of the descending thoracic and thoracoabdominal aorta: preliminary results in 45 patients.

Authors:  E Kieffer; T Richard; J Chiras; G Godet; E Cormier
Journal:  Ann Vasc Surg       Date:  1989-01       Impact factor: 1.466

3.  Assessment of spinal cord integrity during thoracoabdominal aortic aneurysm repair.

Authors:  Michael J Jacobs; Ted W Elenbaas; Geert W H Schurink; Werner H Mess; Bas Mochtar
Journal:  Ann Thorac Surg       Date:  2002-11       Impact factor: 4.330

4.  Intraoperative spinal cord monitoring during descending thoracic and thoracoabdominal aneurysm surgery.

Authors:  Charles C J Dong; David B MacDonald; Michael T Janusz
Journal:  Ann Thorac Surg       Date:  2002-11       Impact factor: 4.330

5.  Transluminal placement of endovascular stent-grafts for the treatment of descending thoracic aortic aneurysms.

Authors:  M D Dake; D C Miller; C P Semba; R S Mitchell; P J Walker; R P Liddell
Journal:  N Engl J Med       Date:  1994-12-29       Impact factor: 91.245

  5 in total
  1 in total

1.  Microsurgical anatomy of the Adamkiewicz artery-anterior spinal artery junction.

Authors:  Hermann Adonis N'da; Louis Chenin; Cyril Capel; Eric Havet; Daniel Le Gars; Johann Peltier
Journal:  Surg Radiol Anat       Date:  2015-12-01       Impact factor: 1.246

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.