Literature DB >> 15509904

Effects of a peracetic acid disinfection protocol on the biocompatibility and biomechanical properties of human patellar tendon allografts.

R J Lomas1, L M Jennings, J Fisher, J N Kearney.   

Abstract

Patellar tendon allografts, retrieved from cadaveric human donors, are widely used for replacement of damaged cruciate ligaments. In common with other tissue allografts originating from cadaveric donors, there are concerns regarding the potential for disease transmission from the donor to the recipient. Additionally, retrieval and subsequent processing protocols expose the graft to the risk of environmental contamination. For these reasons, disinfection or sterilisation protocols are necessary for these grafts before they are used clinically. A high-level disinfection protocol, utilising peracetic acid (PAA), has been developed and investigated for its effects on the biocompatibility and biomechanics of the patellar tendon allografts. PAA disinfection did not render the grafts either cytotoxic or liable to provoke an inflammatory response as assessed in vitro . However, the protocol was shown to increase the size of gaps between the tendon fibres in the matrix and render the grafts more susceptible to digestion with collagenase. Biomechanical studies of the tendons showed that PAA treatment had no effect on the ultimate tensile stress or Young's modulus of the tendons, and that ultimate strain was significantly higher in PAA treated tendons.

Entities:  

Mesh:

Substances:

Year:  2004        PMID: 15509904     DOI: 10.1023/B:CATB.0000046071.11459.bd

Source DB:  PubMed          Journal:  Cell Tissue Bank        ISSN: 1389-9333            Impact factor:   1.522


  5 in total

1.  Production of decellularized porcine lung scaffolds for use in tissue engineering.

Authors:  Jenna L Balestrini; Ashley L Gard; Angela Liu; Katherine L Leiby; Jonas Schwan; Britta Kunkemoeller; Elizabeth A Calle; Amogh Sivarapatna; Tylee Lin; Sashka Dimitrievska; Stuart G Cambpell; Laura E Niklason
Journal:  Integr Biol (Camb)       Date:  2015-10-01       Impact factor: 2.192

2.  The effect of terminal sterilization on structural and biophysical properties of a decellularized collagen-based scaffold; implications for stem cell adhesion.

Authors:  Andrea M Matuska; Peter S McFetridge
Journal:  J Biomed Mater Res B Appl Biomater       Date:  2014-06-03       Impact factor: 3.368

3.  Effects of Chemical Sterilization and Gamma Irradiation on the Biochemical and Biomechanical Properties of Human Tendon Allografts In Vitro Study.

Authors:  Hao-Ran Zhang; Ming-You Xu; Lei Zhang; Hao Zhang; Li Yang; Jie Liu; Jing-Yu Zhang; Yong-Cheng Hu
Journal:  Orthop Surg       Date:  2022-08-24       Impact factor: 2.279

Review 4.  Disinfection of human musculoskeletal allografts in tissue banking: a systematic review.

Authors:  J Mohr; M Germain; M Winters; S Fraser; A Duong; A Garibaldi; N Simunovic; D Alsop; D Dao; R Bessemer; O R Ayeni
Journal:  Cell Tissue Bank       Date:  2016-09-24       Impact factor: 1.522

5.  The effects of irradiation on the biological and biomechanical properties of an acellular porcine superflexor tendon graft for cruciate ligament repair.

Authors:  Jennifer H Edwards; Anthony Herbert; Gemma L Jones; Iain W Manfield; John Fisher; Eileen Ingham
Journal:  J Biomed Mater Res B Appl Biomater       Date:  2016-09-23       Impact factor: 3.368

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.