Literature DB >> 15508169

Bandwidth-modulated adiabatic RF pulses for uniform selective saturation and inversion.

Jan M Warnking1, G Bruce Pike.   

Abstract

Radiofrequency (RF) inversion and saturation pulses with extremely high spatial selectivity and uniform profiles are a requirement for numerous MR techniques, such as pulsed arterial spin labeling and outer volume suppression. Adiabatic pulses used for inversion of longitudinal magnetization are ubiquitous, but the superior selectivity of adiabatic full passages has not been widely exploited for saturation because a simple way of calibrating the amplitude of these subadiabatic pulses is lacking. An analytically derived calibration equation is presented, applicable to a large class of pulses including the hyperbolic secant (HS) pulse and allowing the determination of the precise amplitude required to achieve any effective flip angle. The properties of this calibration are examined, and a highly selective and homogeneous HS saturation pulse is demonstrated. Based on this calibration a new class of RF pulses is developed. These bandwidth-modulated adiabatic selective saturation and inversion (BASSI) RF pulses afford optimal amplitude modulation, achieving uniform profiles at any effective flip angle. BASSI pulses are compared to existing gradient modulated adiabatic pulses in simulations and phantom experiments and shown to be superior in terms of selectivity and homogeneity, while requiring less RF energy. An application of BASSI pulses to pulsed arterial spin labeling is shown. (c) 2004 Wiley-Liss, Inc.

Mesh:

Year:  2004        PMID: 15508169     DOI: 10.1002/mrm.20262

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  6 in total

1.  QUIPSS II with window-sliding saturation sequence (Q2WISE).

Authors:  Ruitian Song; Ralf B Loeffler; Claudia M Hillenbrand
Journal:  Magn Reson Med       Date:  2011-09-27       Impact factor: 4.668

2.  Limits of a localized magnetic resonance spectroscopy assay for ex vivo myocardial triacylglycerol.

Authors:  Robert D O'Connor; Robert J Gropler; Linda Peterson; Jean Schaffer; Joseph J H Ackerman
Journal:  J Pharm Biomed Anal       Date:  2007-09-01       Impact factor: 3.935

3.  Across-vendor standardization of semi-LASER for single-voxel MRS at 3T.

Authors:  Dinesh K Deelchand; Adam Berrington; Ralph Noeske; James M Joers; Arvin Arani; Joseph Gillen; Michael Schär; Jon-Fredrik Nielsen; Scott Peltier; Navid Seraji-Bozorgzad; Karl Landheer; Christoph Juchem; Brian J Soher; Douglas C Noll; Kejal Kantarci; Eva M Ratai; Thomas H Mareci; Peter B Barker; Gülin Öz
Journal:  NMR Biomed       Date:  2019-12-18       Impact factor: 4.044

4.  Acceleration of ASL-based time-resolved MR angiography by acquisition of control and labeled images in the same shot (ACTRESS).

Authors:  Yuriko Suzuki; Noriyuki Fujima; Tetsuo Ogino; James Alastair Meakin; Akira Suwa; Hiroyuki Sugimori; Marc Van Cauteren; Matthias J P van Osch
Journal:  Magn Reson Med       Date:  2017-03-20       Impact factor: 4.668

5.  Cerebral blood flow measurement using fMRI and PET: a cross-validation study.

Authors:  Jean J Chen; Marguerite Wieckowska; Ernst Meyer; G Bruce Pike
Journal:  Int J Biomed Imaging       Date:  2008

Review 6.  Perfusion magnetic resonance imaging: a comprehensive update on principles and techniques.

Authors:  Geon-Ho Jahng; Ka-Loh Li; Leif Ostergaard; Fernando Calamante
Journal:  Korean J Radiol       Date:  2014-09-12       Impact factor: 3.500

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.