Literature DB >> 15507904

Stress transfer of four mandibular implant overdenture cantilever designs.

Steven J Sadowsky1, Angelo A Caputo.   

Abstract

STATEMENT OF PROBLEM: The influence of implant number and cantilever design on stress distribution on bone has not been sufficiently assessed for the mandibular overdenture.
PURPOSE: The purpose of this simulation study was to measure, photoelastically, the biologic behavior of 2 or 3 implants retaining different designs of cantilevered bar mandibular overdentures and to compare load characteristics.
MATERIALS AND METHODS: Two photoelastic models of a human edentulous mandible were fabricated having 2 or 3 screw-type implants (Nobel Biocare, 3.75 x 10mm) embedded in the parasymphyseal area. Bar frameworks using a 7-mm cantilever were fabricated for both models. A clip-retained and a plunger-retained (SwissLoc) prosthesis were fabricated as superstructures for each framework. Vertical loads of 15 and 30 pounds were applied unilaterally to the first molar and 15 pounds to the first premolar on each of the 4 standardized overdenture prostheses. The cantilever was removed from the 2-implant framework and the clip-retained prosthesis was loaded similarly on the first molar with 25 pounds. Stresses that developed in the supporting structure were monitored photoelastically and recorded photographically.
RESULTS: While all 4 prostheses demonstrated low stress transfer to the implants, the plunger-retained prosthesis caused more uniform stress distribution to the ipsilateral terminal abutment compared to the clip-retained prosthesis and provided retention security under tested loads. The plunger-retained prosthesis retained by 2 implants provided better load sharing from the ipsilateral edentulous ridge than the clip-retained prosthesis retained by 3 implants, and lower resultant stresses were seen on the implants.
CONCLUSIONS: Under load, all prosthetic designs demonstrated a low stress transfer to the ipsilateral abutment and to the contralateral side of the arch. The plunger-retained prosthesis retained by 2 implants demonstrated a more uniform stress transfer to the ipsilateral terminal abutment than the clip-retained prosthesis retained by 3 implants and provided more retention, given the implant configuration, prosthetic design and arch form.

Entities:  

Mesh:

Substances:

Year:  2004        PMID: 15507904     DOI: 10.1016/j.prosdent.2004.07.028

Source DB:  PubMed          Journal:  J Prosthet Dent        ISSN: 0022-3913            Impact factor:   3.426


  7 in total

1.  Rehabilitation of the edentulous mandible with implant-supported overdenture using ball attachments and healing abutments: A case report.

Authors:  Jun-Beom Park
Journal:  Saudi Dent J       Date:  2009-10-29

2.  A clinical study on the 6-year outcomes of immediately loaded three implants for completely edentulous mandibles: "the all-on-3 concept".

Authors:  Mustafa Ayna; Keyvan Sagheb; Ralf Gutwald; Henning Wieker; Christian Flörke; Yahya Açil; Jörg Wiltfang; Aydin Gülses
Journal:  Odontology       Date:  2019-07-05       Impact factor: 2.634

3.  Photoelastic stress analysis surrounding implant-supported prosthesis and alveolar ridge on mandibular overdentures.

Authors:  Dorival Pedroso da Silva; Claudia Cazal; Fernanda Campos Sousa de Almeida; Reinaldo Brito E Dias; Rafael Yagüe Ballester
Journal:  Int J Dent       Date:  2010-05-10

4.  Effect of cantilever length on stress distribution around implants in mandibular overdentures supported by two and three implants.

Authors:  Behnaz Ebadian; Ramin Mosharraf; Niloufar Khodaeian
Journal:  Eur J Dent       Date:  2016 Jul-Sep

5.  Analytical Modeling of the Interaction of a Four Implant-Supported Overdenture with Bone Tissue.

Authors:  Bohdan Pelekhan; Maciej Dutkiewicz; Ivan Shatskyi; Andrii Velychkovych; Mykola Rozhko; Liubomyr Pelekhan
Journal:  Materials (Basel)       Date:  2022-03-24       Impact factor: 3.623

Review 6.  Photoelasticity for Stress Concentration Analysis in Dentistry and Medicine.

Authors:  Miriam Marín-Miranda; Ana María Wintergerst; Yoshamin Abnoba Moreno-Vargas; María Lilia Adriana Juárez-López; Cesar Tavera-Ruiz
Journal:  Materials (Basel)       Date:  2022-09-30       Impact factor: 3.748

7.  A Comparison of Biomechanical Properties of Implant-Retained Overdenture Based on Precision Attachment Type.

Authors:  Małgorzata Idzior-Haufa; Agnieszka A Pilarska; Wiesław Hędzelek; Piotr Boniecki; Krzysztof Pilarski; Barbara Dorocka-Bobkowska
Journal:  Materials (Basel)       Date:  2021-05-17       Impact factor: 3.623

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.