Literature DB >> 15505838

Vascular access site complications with the use of closure devices in patients treated with platelet glycoprotein IIb/IIIa inhibitors during rescue angioplasty.

Fernando Boccalandro1, Abid Assali, Kenichi Fujise, Richard W Smalling, Stefano Sdringola.   

Abstract

The objective of this study was to evaluate the effectiveness of two different closure devices in patients undergoing rescue percutaneous coronary intervention (PCI) using IIb/IIIa inhibitors and to compare it with patients undergoing elective PCI. One hundred sixty-two patients undergoing rescue PCI treated with IIb/IIIa inhibitors underwent vascular access site closure (6 Fr Perclose, n = 92, or 6 Fr Angioseal, n = 70). Vascular complications were compared with a sex- and age-matched group (n = 100) of patients undergoing manual compression after sheath removal and a similar group of patients undergoing elective PCI (n = 196). The incidence of access site complications was not significantly different between the three groups undergoing rescue PCI and was not higher than in patient receiving GP IIb/IIIa inhibitors without fibrinolysis (RR = 0.95; 95% CI = 0.88-1.01). In patients undergoing rescue PCI and receiving IIb/IIIa inhibitors, closure devices allow early sheath removal and are associated with similar outcomes compared with manual compression and elective PCI regardless of the type of closure device used.

Entities:  

Mesh:

Substances:

Year:  2004        PMID: 15505838     DOI: 10.1002/ccd.20171

Source DB:  PubMed          Journal:  Catheter Cardiovasc Interv        ISSN: 1522-1946            Impact factor:   2.692


  4 in total

1.  Bleeding complications after contemporary pharmacoinvasive therapy for ST elevation myocardial infarction.

Authors:  Matthew J Gutierrez; Atul Aggarwal; Kristin Gilbert; Burton E Sobel; Harold L Dauerman
Journal:  J Thromb Thrombolysis       Date:  2004-12       Impact factor: 2.300

2.  A cost-minimization analysis of the angio-seal vascular closure device following percutaneous coronary intervention.

Authors:  Frederic S Resnic; Nipun Arora; Michael Matheny; Matthew R Reynolds
Journal:  Am J Cardiol       Date:  2007-01-22       Impact factor: 2.778

3.  The frequency of vascular complications associated with the use of vascular closure devices varies by indication for cardiac catheterization.

Authors:  Emilia Stegemann; Rainer Hoffmann; Steven Marso; Berthold Stegemann; Nikolaus Marx; Thomas Lauer
Journal:  Clin Res Cardiol       Date:  2011-04-11       Impact factor: 5.460

4.  Randomized comparison of effects of suture-based and collagen-based vascular closure devices on post-procedural leg perfusion.

Authors:  H I M Kälsch; H Eggebrecht; S Mayringer; T Konorza; B Sievers; S Sack; R Erbel; K Kroeger
Journal:  Clin Res Cardiol       Date:  2007-09-18       Impact factor: 5.460

  4 in total